connection to a power line equipped with an efficient earthing socket.
4.4.1 - 110 V-60 Hz single-phase machine
In this configuration, the machine is supplied with a power cable with 3 x 16 AWG
gauge. This cable is connected to a single-phase plug with three pins. Attach the
cable to the 110 V-60 Hz single-phase power supply line by installing a 15 A
residual current circuit breaker in between.
Consult the manufacturer for configurations differing from those mentioned above.
If the power cable needs to be extended, use a cable of the same gauge as the
original cable installed by the manufacturer.

5 - Start-up and shutdown

5.1 - Verification of the correct electrical
connection
Plug the cable into the power socket;
Press the run button ("1", Fig. 3.1.1).
The direction of rotation of the worm must be anticlockwise in extruding
mode.
If it turns in the opposite direction, disconnect the machine from the power supply
and contact our nearest dealer.
Note:
In machines connected to a single-phase line and specifically designed for this
system, the rotation direction will be defined directly by the manufacturer.

5.2 - Verification of the presence and efficiency of guards and safety devices

1 - Top lid.
Check that when you open the top lid the machine stops.
The machine must NOT work when the lid is open.
5.3 - Verification of the efficiency of the emergency stop button (Fig. 3.1.1)
With the machine connected to the electricity and the accessory tool moving, press
the stop button (5). The machine must stop.
5.4 - Machine start-up (Fig. 3.1.1)
To start the machine, press the button (4) after having set the selector switch to
extruding mode (1) or kneading mode (3) Fig. 3.1.1, and after having correctly
plugged the cable into the power socket: the machine will start. If the switch is set
to OFF the machine will not start.
5.5 - Machine stop (Fig. 3.1.1)
To stop the machine, press the stop button "5" Fig. 3.1.1.