Rx Test Specification - Alinco DR-235 TMkIII Service Manual

Hide thumbs Also See for DR-235 TMkIII:
Table of Contents

Advertisement

4) RX Test Specification

TEST ITEM
CONDITION
RX Signal
216.05MHz
Sensitivity
223.50MHz
250.05MHz
223.50MHz
NARROW
223.55MHz
RX Distortion
223.50MHz
WIDE
NARROW
RX S/N
223.50MHz
WIDE
223.50MHz
NARROW
Squelch
223.50MHz
Sensitivity
Indication 02
S Meter
223.50MHz
1KHz
3.5KHz/DEV
AF Output
223.50MHz
CTCSS
223.50MHz
Sensitivity
WIDE
223.50MHz
NARROW
DCS Sensitivity
223.50MHz
WIDE
223.50MHz
NARROW
Drain Current
223.50MHz
Power off Current
223.50MHz
Howling
223.50MHz
All manuals and user guides at all-guides.com
ADJ. STANDARD
Less than -7dBu
Less than -8dBu
Less than -3dBu
Less than -8dBu
Less than 6dBu
Less than 4%
More than 40dB
More than 34dB
Squelch Open
Squelch Close
All appears at
20dBu
More than 2W
Open at
500Hz/DEV
Open at
250Hz/DEV
Opens when Test
Equipment is in TX
Opens when Test
Equipment is in TX
Less than 0.65A
Less than 10mA
Don't occur
TEST STANDARD
Less than -6dBu
12dB SINAD
Less than -7dBu
Less than -2dBu
Less than -7dBu
Less than 7dBu
AM 10dB S/N
SSG Output 30dBu
Less than 5%
More than 38dB
SSG Output 40dBu
0.3~3K H z BPF OFF
More than 32dB
Squelch Open
SSG Output -1 OdBu
Squelch Close
SSG Output OFF
All appears at
Decrease SSG level and
25dBu
decrease S Meter level
More than 2W
SSG Output 30dBu
Open at
SSG Output OdBu
500Hz/DEV
88.5Hz
Open at
250Hz/DEV
Opens when Test
255 Code
Equipment is in TX
Opens when Test
Equipment is in TX
Less than 0.65A
Max volume
Less than 10mA
Power off
Don't occur
SSG Output 60dBu
Mod off, Max volume
NOTE

Advertisement

Table of Contents
loading

Table of Contents