9
Commissioning
Read the operating manual and the chapter 4 "Safety" carefully before commissioning and observe them.
Before switching on, check that
• there are no loose parts on the thicknessing table and that all tools have been removed,
• the guards are fitted in accordance with regulations,
• the extraction system is connected and in working order,
• the direction of rotation is correct,
• the V-belts are perfectly tensioned
• and no persons are in a danger zone of the machine
9.1
Switching the Machine ON and OFF
N
9.1.1 Switching ON
• Turn the main switch (H) to position "I".
• Start cutter block with push button (M):
The machine starts with automatic star-delta switching.
9.1.2 Switching OFF
• Switch off the cutter block with push button (M):
The machine is braked
• Turn the main switch (H) to position "0".
Undervoltage protection ensures that the machine is switched off in the event of a power failure and does not
restart automatically when power is applied again.
Note: The machine is equipped with a motor protection switch which switches off the motor
in the event of an overload. In this case, wait a few minutes until the protective contacts
have cooled down again. Only then can the machine be restarted.
BA_PH_335-20_EN_07-22.docx
U
A
D
Figure 15: Control panel with main switch
B
M
H
28