Troubleshooting Via Idm - Daktronics PROLINK ROUTER 605 Series Installation And Maintenance Manual

Table of Contents

Advertisement

Code
Description
F
0
D
EPLD error
F
0
E
EPLD oscillator error
F
0
F
EPLD firmware is missing or corrupt
F
1
0
Firmware error
F
1
1
ProLink5 configuration error
F
1
2
PLR display error
F
1
3
VIN voltage error
F
x
x
Other self-test error
Note: If a CAN sensor is not available for field use, the CAN error can be ignored; the
operator should fail the PLR only if the ERR LED is lit.

Troubleshooting via IDM

Daktronics Intelligent Device Management (IDM) is an internet-based diagnostic system
that analyzes the data collected from Daktronics equipment to identify malfunctions,
errors, and other issues. The IDM website is the primary source for accessing the
diagnostic data. For more information on using IDM, refer to the Daktronics Intelligent
Device Management User Manual (DD2097912).
If a PLR-controlled display section shows either a blank module or incorrect data, follow
these steps:
1. Open the IDM application.
2. Click any visible diagnostic errors. The status window opens on the right side. Refer to
Figure 36. If IDM does not show any visible errors, proceed to Troubleshooting at the
PLR605X Display (p.37) or Troubleshooting at the PLR615X Display (p.38).
Visible diagnostic errors
Status window
Figure 36: IDM Troubleshooting
Diagnostics & Troubleshooting
36
Help icon

Advertisement

Table of Contents
loading

Table of Contents