When the self-test is complete, disconnect power, remove all loopback connections,
reconnect cables, and restart power. Refer to Figure 35 and Self-Test Mode Messages for
further information on the error messages.
ERR
0
1
Figure 34: Test-in-Progress Pattern

Self-Test Mode Messages

While in self-test mode, the PLR615X status LEDs may display a message listed in Figure 35.
If the ERR LED lights up, the PLR should be sent in for repair. Daktronics field personnel may
also reference the ProLink Router 615X (PLR615X) Self-Test Manual (DD2469872) for further
information.
The error code descriptions are listed in the table below.
Code
Description
F
0
1
ProLink6 (coax) Port A error
F
0
2
ProLink6 (coax) Port B error
F
0
5
ProLink5 (SATA) Port A error
F
0
6
ProLink5 (SATA) Port B error
F
0
8
Fan control error
F
0
9
Internal voltage error
F
0
A
Temperature error
F
0
B
ID error
F
0
C
Serial flash error
Code
ERR
2
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Figure 35: PLR615X Self-Test Mode Messages
Diagnostics & Troubleshooting
35
2
0
1
All tests passed
ISAC/CAN error
F0B, F09, F0A, F0C, F0D, F0E
F01, F02
F05, F06
F08
F13
F10, F0F
Unused, future use