ERROR LOG (SELF-DIAGONOSIS RECORD AND INDICATION)
5.3.1 Outline
By using the special setting and adjustment software, data related to abnormal operation (history) stored in the projector can be load.
On the basis of contents "LED (INDICATOR) WARNING INDICATONS" set and lamp use time, internal and external temperature,
and ther data prior to the previous usage time can be viewed as a table.
HOW TO LOAD THE DATA FROM UNIT
(1) Install the software in a personal computer and connect
by RS-232C IN terminal (use cross cable).
(2) Set the projector to stand-by mode.
(3) Start the setting and adjustment software.
(4) Click the [Read Log] button and save the TEXT file. Data
become the latest data so as to go below.
(5) The first number is error code.
(6) Click the [Clean Log] button and delete all data stored in
projector.
SYSTEM TIME(Min)
ERROR CODE
INSIDE TEMPERATURE
F1, 17, 568, 1840, 42, 44, 1, 00, 00
LAMP TIME(Min)
SETUP NUMBER
OUTSIDE TEMPERATURE
ERROR LOG SCREEN ITEMS
No
Content
1
The lamp don't light
2
The lamp turn off
3
The lamp cover opening
4
Power board occurs error
5
The fan lock
6
The internal temperature is too high
7
The exterior temperature is too high
8
DDM reset or start error
9
Can't communicate with DDM
10 SCALER board occurs error
11 Lens barrier occurs error
12 Lamp time warning
13 Just after power on
14 After power on, once a hour
15 When power was off (Include emergency)
16 When a lamp was off by a sleep time function
POWER STATUS
0: STAND-BY MODE
1: POWER ON MODE
2: COOLING MODE
NOT USED
POWER STATUS
code
01
06
15
1A
07
0D
08
09
17
18
0E
0F
16
19
1B
02
F0
F1
F2
20
Log
Remarks
Other fans
PWM Fan
DDM reset
DDM did not start.
CMD IC on MD board did not start.
Driver IC on DD board did not start.
(No.PA045<Rev.001>)1-25