5. INSTALLATION

5.1.

INSTALLING THE OUTDOOR UNIT

Make sure that the outdoor unit is fastened securely to prevent strong wind.
-
-
Install the unit in accordance with the information contained in the table below.
-
lf installing in marine environments or in locations that are very high in relation to the
ground floor and/or in the presence of strong winds, use a locking plate and fit it
against the wall so that the compressor can operate properly.
lf installing in a normal location, the structure of the support base must be made of
-
concrete or material with equivalent strength and have necessary support ability.
Alternatively, adopt by all the support measures needed to prevent the unit from
vibrating.
-
lf you decide to protect the outdoor unit from rain and direct sunlight with a special
canopy, be careful not to hinder heat radiation by the compressor.
-
Do not grow plants or raise animals in the vicinity of the compressor because the
heat could affect normal growth.
-
Make sure there is a suitable distance from ceilings, walls, furniture and other
obstacles.
Secure the unit away from heat sources and/or flammable gases.
-
The installation base and support frame must be adequate and secure. The machine
-
must normally be installed on a flat surface.
Installation space
Please be sure to meet the following installation space requirements when selecting the
installation site:
The following figures show the right and the wrong installations:
Wrong
Installation
Right
Installation
A>100mm ; B>2000mm ; C>300mm ; D>300mm