Stepper Motor Louver
The STEPPER MOTOR 1 and 2 moves the louver up or down,
depending upon selections made at the remote control.
The motor is connected to the indoor control board at CN5
and CN5-1

Fan Motor

The Fan Motor is a variable speed motor. The air volume will
vary with the speed of the compressor, or it can be set at the
remote control to maintain a single speed.
The Fan Motor is connected to the indoor control board via
PLUG CN-9.
INDOOR UNIT CONTROLS AND COMPONENTS

Emergency Button

If the remote control is non-functional, the Emergency
Button can be used. 73F -78F degrees will be maintained, until
commands are received via the remote control.