F12/Led1: 1 Flash - Haier GE Appliances AW24TL2HFA Service Manual

Ductless split heat pump
Table of Contents

Advertisement

Error Code
(Indoor/Outdoor)

F12/LED1: 1 Flash

EEPROM Error
Complete the "Check This First" Flow
Chart before continuing.
Models:
AW24TL2HFA
AW30TL2HFA
AW36TL2HFA
ASYW24TRDFA
ASYW30TRDFA
ASYW36TRDFA
1U24TL2HFA
1U3036TL2HFA
ASH124TRDFA
ASH3036TRDFA
Wiring Diagram Reference
COMPRESSOR
Electrical Shock Hazard
Capacitor retains charge a er
voltage at capacitor has dissipated
(<10V DC) with hand held voltmeter
before servicing. LED2 light
between CN24 and CN26 should be
12K-18K
Error Codes and Troubleshooting
Outdoor Board Diagram
OUTDOOR UNIT WIRING DIAGRAM
El capacitor re enecargaunavez
voltaje del capacitor se haya disipado (<10V
DC) apoyando la mano sobre el vol metro
antes de realizar el servicio técnico. La luz
LED2 que se encuentra entre CN24 y CN26
deberá estar apagada.
OUTDOOR UNIT WIRING DIAGRAM
ERROR CODES AND TROUBLESHOOTING
Start
After 10 minutes with the power
off, the 1-flash reappears with
power turned back on?
Yes
No
Replace
PCB
Riesgo de Descarga Eléctrica
The 10-minute
reboot has
corrected the
issue
0011520512
Y/G
Y/G
BL
BR
BR
Y/G
B
BR
BL
Risque de choc électrique
Le condensateur conserve sa charge après la
coupure de l'alimenta on électrique. Avant
de procéder à une répara
courant au condensateur s'est dissipé
(<10 VCC) à l'aide d'un voltmètre manuel. Le
voyant LED2 entre CN24 et CN26 doit être
éteint.
0011509127A