E14 - Haier GE Appliances AW24TL2HFA Service Manual

Ductless split heat pump
Table of Contents

Advertisement

Error Code
(Indoor)

E14

Indoor Fan Motor Failure
Complete the "Check This First" Flow
Chart before continuing.
Models:
AW24TL2HFA
AW30TL2HFA
AW36TL2HFA
ASYW24TRDFA
ASYW30TRDFA
ASYW36TRDFA
Error Codes and Troubleshooting
See following page
for wiring diagram and
relevant color-coded
test positions.
With the power off, turn
the fan by hand. Does it
move / rotate smoothly?
No
Yes
Re-apply power. Does the
fan come on and spin?
Yes
Measure DC voltage at fan
motor plug CN9 between
the Pin 7 (BLUE) and Pin
4 (BLACK) wire while
spinning the fan motor.
Does it generate 2~9VDC?
No
Yes
Replace the main
Replace the fan
board.
Measure DC voltage at fan motor
plug CN9 between the Pin 7
(BLUE) and Pin 4 (BLACK) wire
while spinning the fan motor.
Does it generate 2~9VDC?
No
Yes
Replace the main
Replace the fan
board.
ERROR CODES AND TROUBLESHOOTING
Start
Check the incoming voltage. Is it 208/230VAC
(+/- 10%) between L1/L2? 104/115VAC (+/-
10%) from L1 to GROUND and L2 to GROUND?
Yes
No
Replace the fan
motor
No
Does it measure 300~380VDC
Measure DC voltage at fan motor
plug CN9 between Pin 5 (WHITE)
and Pin 4 (BLACK).
Does it measure between
13.5-16.5VDC?
motor
Measure DC voltage at fan
motor plug CN9 between Pin 6
(YELLOW) and Pin 4 (BLACK).
Yes
Does it measure between
motor
Fix incoming
power supply
Measure DC voltage at fan
motor plug CN9 between Pin
1 (RED) and Pin 4 (BLACK).
(+/-10%)?
No
Yes
No
Yes
Replace the
main board.
2-6VDC?
No
Replace the
main board.
Replace the
main board.
PAGE 57