Zoeller 132 Installation Instructions

Zoeller 132 Installation Instructions

Drain pump system

Advertisement

Quick Links

Product information presented
here re fl ects con di tions at time
of publication. Consult factory
re gard ing dis crep an cies or
in con sis ten cies.
Notice to Installer: Instructions must remain with installation.
1. Inspect your unit. Occasionally, prod ucts are dam aged during ship ment. If the unit is damaged, contact your dealer before using. DO NOT remove
the test plugs from the pump.
2. Care ful ly read the literature provided to familiarize yourself with specifi c details regarding installation and use. These ma te ri als should be re tained
for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of elec tri cal shock, a prop er ly ground ed receptacle of
grounding type must be in stalled and pro tect ed by a ground fault circuit
in ter rupt er (GFCI) and in ac cor dance with National Elec tri cal Code and
lo cal codes. (SEE WARNING BELOW).
2. Make certain that the receptacle is with in the reach of the pump's pow er
supply cord. DO NOT USE AN EX TEN SION CORD. Extension cords
that are too long or too light do not deliver suf fi cient voltage to the pump
motor. But more im por tant, they could present a safety hazard if the
in su la tion were to become damaged or the connection end were to fall
into the sump.
3. Testing for Ground. As a safety mea sure, each elec tri cal outlet should
be checked for ground using an Un der writ ers Lab o ra to ry Listed cir cuit
analyzer which will in di cate if the pow er, neutral and ground wires are
correctly con nect ed to your outlet. If they are not, call a qualifi ed elec-
tri cian.
4. For Added Safety. Pump must be con nect ed to a 3-prong ground ed
outlet in ter rupt er de vice (ground fault circuit in ter rupt er).
5. FOR YOUR PROTECTION, ALWAYS DIS CON NECT PUMP FROM
ITS POWER SOURCE BE FORE HAN DLING. Single phase pumps
are sup plied with a 3-prong ground ed plug to help protect you against
the possibility of electrical shock. DO NOT, UNDER ANY CIR CUM -
STANC ES, RE MOVE THE GROUND PIN. To re duce the risk of electri-
cal shock, a properly grounded re cep ta cle of ground ing type must be
installed and pro tect ed by a ground fault circuit interrupter (GFCI) in
ac cor dance with national electrical code and local codes.
6. Installation and checking of electrical cir cuits and hard ware should only
be performed by a qualifi ed licensed elec tri cian.
7. Risk of electric shock - These pumps have not been investigated for
use in swimming pool areas.
8. According to the state of California (Prop 65), this product contains
chemicals known to the state of California to cause cancer and birth
defects or other reproductive harm.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
DRAIN PUMP SYSTEM
MODEL132 (Preassembled)
INSTALLATION IN STRUC TIONS
PREINSTALLATION CHECK LIST
© Copyright 2011 Zoeller Co. All rights reserved.
SEE BELOW FOR LIST OF CAUTIONS
1. Check to be sure your power source is adequate for handling the voltage
requirements of the motor, as in di cat ed on the pump or basin plate.
2. Make sure the pump electrical supply cir cuit is equipped with fuses or
circuit breakers of proper ca pac i ty. A sep a rate branch circuit is rec om -
mend ed, sized according to the National Elec tri cal Code for the current
shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be in stalled to meet local
codes. Unit must be vented. Some states require this unit to be installed
by a qualifi ed licensed plumb er. DO NOT USE AN AUTOMATIC PLUMB-
ING VENT DEVICE SIM I LAR TO A "PRO-VENT".
4. Repair and service should be performed by Zoeller Pump Com pa ny
Authorized Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UN NEC ES SARY CY-
CLING OF PUMP.
6. Dewatering pumps are not designed or intended for han dling raw sew-
age.
7. Maximum operating temperature for 132 Drain Pumps must not exceed
110°F (43°C).
8. For health reasons, do not unplug, turn off, or disable pump and use
pump tank system as a way to fi ll up a sink or laundry tray, etc.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are
tested to UL Standard UL778. CSA Certifi ed pumps are certifi ed to
CSA Standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
1
SECTION: 6.10.046
FM2113
Supersedes
visit our web site:
www.zoeller.com
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________
0111
1004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 132 and is the answer not in the manual?

Questions and answers

Summary of Contents for Zoeller 132

  • Page 1 ING VENT DEVICE SIM I LAR TO A "PRO-VENT". into the sump. 4. Repair and service should be performed by Zoeller Pump Com pa ny 3. Testing for Ground. As a safety mea sure, each elec tri cal outlet should Authorized Service Station only.
  • Page 2 If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must be by Zoeller Authorized Service Stations. © Copyright 2011 Zoeller Co. All rights reserved.
  • Page 3 Figure 1 is a typical confi guration for installation of the drain system. The actual confi guration will vary de pend ing on your PIPING SHOWN ONLY cab i net and sink confi guration. FOR CLARITY. Figure 1 STANDARD INSTALLATION SK2001 © Copyright 2011 Zoeller Co. All rights reserved.
  • Page 4 ¼ - 20 Hex. Hd. Nut - S.S. N/A* N/A* Pipe Cap w/o-ring N/A* N/A* O-Ring N/A* N/A* *When ordering this item, order the hardware pack item #6. Drain Pump 132 SK2833 © Copyright 2011 Zoeller Co. All rights reserved.