Emergency Use; Product Warnings; Product Identification; Technical Characteristics - Genius BLIZZARD 500 Translation Of The Original Instructions

Table of Contents

Advertisement

not specifically authorised and trained to do so.
- Do not allow the control devices to be used by children or persons
with mental and physical deficiencies unless they are supervised
by an adult who is responsible for their safety.
!
During manual operation, gently guide the leaf the whole way, do not
push it and let it slide freely.

3.4 EMERGENCY USE

In emergencies or if there is a fault, turn off the power supply to the
automation . If the leaf can be moved safely by hand, use the MANUAL
OPERATION mode; otherwise place the automation out of service until
it has been reset/repaired.
In the case of a breakdown, the automation must be reset/repaired
exclusively by the installer/maintenance technician.

3.5 PRODUCT WARNINGS

Risk of fingers and hands being trapped between the rack, pinion and
casing (2).
 5 Technical Data
Supply voltage
Electric motor
Start-up capacitor
Max power
Thermal protection
Max thrust force
Starting thrust force
Pinion
Max sliding gate section length
Max sliding gate section weight
Sliding gate section speed
Ambient operating temperature
Type of use
Continuous use time (ROT) 20°C*
Ingress Protection
Dimensions (LxDxH)
Gear motor weight
* The ROT technical data refers to the operation with the electronic boards GENIUS SPRINT 382 and SPRINT 383 (maximum ambient tem-
perature 20°C).
BLIZZARD 500-900
BLIZZARD 500
230 V~ (+6%...-10%) 50 Hz 115 V~ (+6%...-10%) 60 Hz 230 V~ (+6%...-10%) 50 Hz 115 V~ (+6%...-10%) 60 Hz
Asynchronous single phase
Asynchronous single phase
10 μF
40 μF
350 W
340 W
140 °C (automatic rearming)
140 °C (automatic rearming)
390 N
250 N
300 N
220 N
Z16 Module 4
Z16 Module 4
15 m
15 m
500 kg
500 kg
12 m/min
14 m/min
-20 °C - +55 °C
-20 °C - +55 °C
Residential buildings/Apartment
Residential buildings/Apartment
complexes
complexes
9 min
11 min
IP44
IP44
297x170x256
297x170x256
9.2 kg
9.2 kg

3.6 PRODUCT IDENTIFICATION

FAAC S.p.A. Soc. Unipersonale
Via Calari, 10 - 40069 Zola Predosa BOLOGNA
Italy
••••••
••••••
MM/YY

3.7 TECHNICAL CHARACTERISTICS

GENIUS BLIZZARD 500 and BLIZZARD 900 series gear motors
are equipped with a pair of magnetic limit switches and corre-
sponding limit stop sensors. There is no control system included:
BLIZZARD 500-900 must be connected to a GENIUS electronic board
for controlling 230 V~/115 V~ motors (depending on the version)
for sliding gates.
Movement cannot be reversed: To operate the gate manually, follow
the instructions in § 5.5.
BLIZZARD 900
Asynchronous single phase
12.5 μF
530 W
140 °C (automatic rearming)
590 N
410 N
Z16 Module 4
15 m
900 kg
12 m/min
-20 °C - +55 °C
Residential buildings/Apartment
complexes
11 min
IP44
297x170x256
10 kg
7
Sales code
Product name
PROG
IDENTIFICATION NUMBER
Month/year of production +
progressive number for the
•••
month of production
E.g.:
0115 0001
Asynchronous single phase
50 μF
600 W
140 °C (automatic rearming)
540 N
380 N
Z16 Module 4
15 m
900 kg
14 m/min
-20 °C - +55 °C
Residential buildings/Apartment
complexes
11 min
IP44
297x170x256
10 kg
532102 - Rev.B
 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blizzard 900

Table of Contents