5. Put the signal cable so that no more than 4 cm of the sheath is visible, as shown in the figure
below. Tighten the fixing bolts.
6. Loosen four screws in the figure shown below and open the cover.
7. Put the signal cable through the cable protector.
Cable
protector
1-16
Taping
Within 4 cm
Plate
Flat
washer
CABLE GLAND
How to fasten signal cable in cable gland
Antenna unit chassis, cover opened
Antenna unit chassis, cover opened
Shield wire
Sheath
Bolt
Gasket
Four screws