Fan 1-Phase 115 / 230 V - Bosch rexroth MS2N03-A Operating Manual

Synchronous servomotors
Table of Contents

Advertisement

50 / 72
Electrical connection

7.4.13 Fan 1-phase 115 / 230 V

Fig. 20: MS2N Fan connection 115/ 230 V
Fig. 21: RLSxxxx_Single components fan
connector
Table 10: Connector fan unit for MS2N__-____A (U
230 V ) / MS2N__-____B (U
N
Assignment
1
L1 230 V
2
N
3
L1 115 V
PE
Remark: The plug insert can be mounted in
any position into the connector housing. There-
with, the cable output direction can be done in
steps of 90 degrees.
Protection by integrated thermal protection
MS2N Fan 115 / 230 V with integrated thermal
protection do not need an external motor protec-
tive switch.
Bosch Rexroth AG
115 V)
N
Connection
Screwed connection
0.5 ... 1.5 mm
2
MS2N
R911347581, Edition 05