Endcap
window
Figure 11. HEPA filter installation details

Removing or Changing the Screen

Caution: Always de-energize the unit using proper lockout-tagout (LOTO) procedures when cleaning,
lubricating, or performing any other maintenance, troubleshooting, or repair.
Tools and PPE Required:
Cut resistant gloves
9/16" socket (for 3/8" bolts)
1/2" deep socket with 6" or longer extension
To remove or inspect the screen you need to access the Stage 2 cutting chamber. The screen will be exposed
under the cutting chamber drawer. Follow the instructions in the next section to access the Stage 2 cutting
chamber.

Accessing the Stage 2 Cutting Chamber Before Removing the Screen

Caution: Always de-energize the unit using proper lockout-tagout (LOTO) procedures when cleaning,
lubricating, or performing any other maintenance, troubleshooting, or repair.
Warning: NEVER reach into the cutting chamber with bare hands.
Filter
band
Filter
band
clamp
Endcap
latches
Filter
endcap