The identification of errors within the SE2AG chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the
event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous
flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant
device number will be displayed through the LED (Series of flashes which must be counted).
LED Error Codes
Number of LED
Flashes
02
03
04
05
06
07
08
09
10
13
All manuals and user guides at all-guides.com
SE2AG SELF DIAGNOSTIC SOFTWARE
Error Description
Balancer error.
DC error.
Inverter error.
NVM error.
IIC error.
HDMI error.
Digital error.
Tuner error
SP error
RTC error
- 7 -
Checked
In normal mode.
In normal mode.
In normal mode.
In initialisation state.
In normal mode.
In normal mode.
Adds error to error menu.
In normal mode.
Adds error to error menu.
In initialisation state.
Adds error to error menu.
In initialisation state.
Adds error to error menu.
In initialisation state.
Adds error to error menu.
Action
Goes into standby.
Goes into standby.
Goes into standby.
Goes into standby.
Goes into standby.