4: If you want to hang on the wall, turn the DC plug down until 0 degrees and closed
the desk stand; as shown in Figure 16
Note: If the power adapter is not plugged in, the icon

3.4.2 Sensor Operation Verification

The following steps verify proper operation of the sensors prior to installing the sensor
array.
1. Verify proper operation of the rain gauge. Tip the sensor array back and forth several
times. You should hear a "clicking"sound within the rain gauge. Verify the rain reading on
the display console is not reading 0.00. Each "click" represents 0.3mm of rainfall.
2. Verify proper operating of the wind speed. Rotate the wind cups manually or with a
constant speed fan. Verify the wind speed is not reading 0.0.
3. Verify proper operation of the indoor and outdoor temperature. Verify the indoor and
outdoor temperature match closely with the console and sensor array in the same location
(about 3m apart). The sensors should be within 2°C (the accuracy is ±1°C). Allow about
30 minutes for both sensors to stabilize.
4. Verify proper operation of the indoor and outdoor humidity. Verify the indoor and
outdoor humidity match closely with the console and sensor array in the same location
(about 3m apart). The sensors should be within 10% (the accuracy is ± 5%). Allow about
30 minutes for both sensors to stabilize.
Figure 15
Figure 16
9
will display .