eleCTRICAl DATA

Wire Size
Fuse/Circuit Breaker
Grounding
Receptacle
Plug/Outlet/Circuit Rating
Model
Breaker or T-D Fuse
CP14
CP18
CP24
6
ELECTRIC SHOCK HAZARD
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
installed by a qualified electrician and conform to
the National Electrical Code and all local codes
which have jurisdiction.
Failure to do so can result in personal injury or
death.
Not following the above WARNING could result in fire or
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
Use ONLY wiring size recommended for single outlet branch circuit.
Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on unit's
rating plate. Proper circuit protection is the responsibiity of the homeowner.
Unit MUST be grounded from branch circuit through service cord to unit, or through separate
ground wire provided on permanently connected units. Be sure that branch circuit or general
purpose outlet is grounded. Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet. (CP 14, 18, 24)
The field supplied outlet must match plug on service cord and be within reach of service cord.
Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above
for proper receptacle and fuse type.
Circuit Rating
Plug Face
(NEMA#)
125V - 15A
5 - 15P
250V - 15A
6 - 15P
250V - 20A
6 - 20P
WARNING
NOTICE
FIRE HAZARD
Power Cord
Wall Outlet
Length (ft.)
Appearance
6
4
4