Unit Setup Menu - Dometic Go Power! C Series User Manual

Table of Contents

Advertisement

OPERATION
INVERTER
VAC OUT
ON/OFF
120 V
60.0 Hz
CHARGER
ON/OFF
ENTER / SET
INVERTER
Temperature
ON/OFF
Batt : 20.0°C
Trans : 30.5°C
Fets : 30.6°C
CHARGER
ON/OFF
INVERTER
Unit Fault Code
ON/OFF
No Fault
CHARGER
ON/OFF
Menu Heading
01 Search Watts
02 LowBatCutOut
03 VAC Dropout
04 Max.Cha Time
05 Battery Type
06 Charge Rate
07 Final Charge
08 ABS Chg Time
09 Equalization
10 Rebulk Volt
1. SEARCH WATTS
The search watts feature helps save the battery power by reducing the
able load.
®
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
BACK
®
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
ENTER / SET
BACK
®
SHORE POWER
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
ENTER / SET
BACK
Selections / Adjustments Range
Gel, Flooded, AGM 1, AGM 2, Custom
The first value displays the AC voltage measurement at the inverters output
terminals.
When in inverting mode this reading is displaying the inverters output
voltage.
When in charging or AC pass through mode, the display is showing the AC
voltage that is passing through the
(utility or generator)
4. TEMPERATURE
Batt: Displays the temperature of the
which should be connected to the battery bank
Trans: Displays the temperature of the main power transformer inside the
.
Inverter/Charger
Fets: Displays the temperature of the field effect transistors (FETs) inside
the
.
Inverter/Charger
5. FAULT CODE
This screen will display a code to compliment the audible beep that is emitted
when a fault has occured. If there are no faults, this screen will say No Fault.

4.5 UNIT SETUP MENU

OFF, 5 - 50W
9.0 - 12.2 VDC
80 - 100V
0.0 - 25.5 HR
50% (IC 2000); 40% (IC 3000)
Multi-Stage, Float, Silent
0.5 - 24.0 HR
Active/Inactive
12.0 - 16.0 VDC
Inverter/Charger
from the AC power source
Inverter/Charger
Inverter/Charger
Default Setting
10.5 VDC
12.0 HR
AGM 1
Multi-Stage
2.0 HR
Inactive
12.1 VDC
output to search pulses when there is no detect-
gpelectric.com | [page 21]
battery temp sensor
5W
85V