4.4 UNIT READINGS MENU

Menu Heading
INVERTER
DC Status
ON/OFF
11.68 V
0.0 A
CHARGER
PT
ON/OFF
ENTER / SET
INVERTER
AC INPUT
ON/OFF
0 A
0 V
0 Hz
CHARGER
ON/OFF
ENTER / SET
[page 20] | gpelectric.com
Selections / Adjustments Range
1. DC STATUS
The first value: 11.68 V displays the voltage (VDC) from the battery bank
®
connected to the
resolution.
SHORE POWER
The second value: 0.0A displays the battery current (VDC) either being dis-
UNIT READINGS
UNIT SETUP
charged (inverting mode) or charged (charging mode) from/into the battery
REMOTE SETTINGS
bank.
A negative value, e.g. -35.0A shows that the batteries are dis-charging and
the
Inverter/Charger
BACK
A positive value, e.g. 40.0A shows that the batteries are charging and the
Inverter/Charger
State indicator: PT - Pass Through; PS - Powershare; CHG - Charging; INV:
Inverting
2. AC INPUT
The first value is showing the total AC Amps being used by the inverter for
®
charging and for powering any AC Loads. This reading is always displayed
as a positive number. If the charger is using 15A to charge the batteries
and the connected AC load is using 10A then the total AC Input value is
SHORE POWER
displayed as 25A.
UNIT READINGS
UNIT SETUP
REMOTE SETTINGS
The second value is showing the voltage (AC) of the connected AC Power
source (Utility or Generator). This will usually read 120V.
The third value is showing the frequency of the connected AC Power source
BACK
(Utility or Generator). This is displyed as a unit of frequency: Hertz (Hz).
3. VAC OUT
DC
11.68V
0.0A
AC INPUT
0 A
0 V
0 Hz
VAC OUT
120 V
60.0 Hz
Temperature
Batt: 20.0°C
Trans: 30.5°C
Fets: 30.6°C
. This reading is displayed with a 0.01 VDC
Inverter/Charger
is inverting.
is in charging mode.
OPERATION
Default Setting
Read Only