INSTALLATION

3.5 MOUNTING PROCEDURE

To mount the GP-ICR-50 in a wall, the opening behind the wall must be at least 2" (5cm) of depth to allow room for the remote and cable.
1. Cut a 3" x 5" rectangular opening in the wall, ensure there is enough material for the screws to securely mount the remote.
2. Use the GP-ICR-50 as a template for the 4 holes, mark the positions of the 4 holes with a pencil/pen.
3. Drill the 4 pilot holes for the #8 x 3/4" screws.
4. Route one end of the remote control cable through the wall opening to the Inverter / Charger, plug this end into the REMOTE port.
5. Take the other end of the remote cable and plug it into the rear of the GP-ICR-50. The remote should power up if the
Inverter/Charger
is connected to the battery bank. All power to operate the GP-ICR-50 is provided by the
through the remote cable.
Inverter/Charger
6. When the remote powers up, secure the remote control unit to the wall using the four Phillips screws supplied.
4.9"
(12.45cm)
Panel /
Wall
Mounting
Screws
Inverter/Charger
2.8"
(7.1cm)
Remote Control Port
Remote Cable
gpelectric.com | [page 15]