Download Print this page

FireplaceXtrordinair 21 TRV (Bed & Breakfast) Brochure & Specs page 34

Fireplacextrordinair gas fireplace brochure

Advertisement

Fireplaces
The dimensions and clearances on this
page are for reference only!
Refer to the Owner's Manual prior to
installation
S P E C IF IC A T IO N S
Height (including standoffs)
Width
Depth
Flue Diameter
Unit Weight
Burner System
Glass Area
(will vary slightly with face plate design)
Powerful Fan
Power Duct Option
*Gas appliance performance can be affected by negative pressure in the home and by prevailing atmospheric conditions. Efficiency may vary de
PERFO RM A NCE*
or fire officials about restrictions and installation requirements in your area.
Heating Capacity*
BTU Input High/Output Low (NG)*
BTU Input High/Output Low (LP)*
Overall Efficiency*
(maximum venting)
AFUE*
CO M B UST IB LE CLEA R A NCES
All Measurements taken from
fireplace face.
D= To Side Facing
A= To Mantel
E= Front Hearth
B= To Top Facing
F= Hearth Width
C= To Sidewall
T EST ING & INSTA LLAT IO N INFO RM AT IO N
Tested and Listed by OMNI-Test Laboratories Inc. to ANSI Z21.88b-2001 "Vented Gas-Fired Direct Fireplace Heater." Must be installed
in accordance with all local codes, if any: if not, follow ANSI Z223.1 and the requirements listed in the Owner's Manual.
33
Section 3 - Installation
34
Gas Fireplaces
21
TRV
21 TRV - Bed & Breakfast
35
7
"
8
20
1
" Front
8
15"
8"
86 lbs.
Ember-Fyre™*
16" W x 20 1/2" H = 303 sq. in.
YES - 90 CFM
(Optional)
NO
*Ember-Fyre™ Protected By U.S. Patent #6,602,068, #6,443,726 and other patents pending.
Up to 650 Sq. Ft.
16,500 (high) 10,500 (low)
16,500 (high) 9,380 (low)
82.2% (NG) 79.5% (LP)
63% (NG) 63% (LP)
Always consult the Owner's Manual before beginning any installation. Installation and framing informati
The Bed & Breakfast fireplace
requires a 1" minimum clearance
from face to sidewall. Combus-
tibles can be installed up to the
standoffs on the unit. If a mantel
is used please see Owner's
Manual for minimum clearances.
The height of the Bed & Breakfast
fireplace enclosure must be a
minimum of 48" above the base
of the fireplace.
If placed on a raised hearth,
the ceiling above the Bed &
Breakfast must be at least 57"
measured from the base of the
fireplace.
564
SS
564 Space Saver
33
1
"
4
36
1
"
4
1
1
16
"
"
(Includes
clearance)
4
2
8"
155 lbs.
2 Stage Pan Burner
30
1
" W x 18
1
" H = 564 sq. in.
2
2
YES - 180 CFM
(Optional)
NO
Up to 950 Sq. Ft.
20,500 (high) 5,100 (low)
20,500 (high) 4,200 (low)
76.5% (NG) 74.2% (LP)
64% (NG) 66% (LP)
A = 38
1
"*
2
(measured from base of fireplace)
B = 0"
C = 1"
D = 0"
E = None Required
F = None Required
*0 to 12" maximum mantel depth.
See Owner's manual for details
864
TRV
864 TRV
38
3
"
8
41"
3
19
"
1
"
(Includes
clearance)
4
2
8" (
")
5
Top vent can be reduced to 6
⁄8
205 lbs.
2 Stage Tube Burner
36" W x 24" H = 864 sq. in.
YES - 180 CFM
(Optional)
YES (One Only )
Up to 1,400 Sq. Ft.
31,000 - 6,700
31,000 - 5,200
80% (NG) 81% (LP)
68.3% (NG) 69.8% (LP)
A = 40 3/4" to 48 3/4"*
(measured from base of fireplace)
B = 0"
C = 1"
D = 0"
E = None Required
F = None Required
*Will vary depending mantel depth.
0 to 12" maximum mantel depth.
See Owner's manual for details
Note: Each face plate design varies
in dimension slightly.

Advertisement