Climatic conditions:
Type
Operating temperature
Storage temperature
Relative humidity
Degree of protection
Atmosphere
Casing material
Mechanical protection:
Type
Resistance to vibrations
Shock resistance
Type
Breakdown voltage
Insulation resistance
Impulse voltage
Safety class (protection
against electric shocks)
Operating classification
Ball test
Software class
Type of mounting
Certification
Conformity
NTR 756 D / e
Standard
IEC 60068-2-14
IEC 60068-2-1/2
IEC 60068-2-30
IEC 60529
Standard
10-57 Hz: 0.075 mm peak
57-150 Hz acceleration: 9.8 m/s²
IEC 60068-2-6
Scrolling: 1 octave/Minute
80 minutes in each direction (X, Y, Z)
Acceleration: 147 m/s², duration: 11 ms
IEC 60068-2-27
3 times in each direction (X, Y, Z)
Standard
1500 VAC/50 Hz/1 mA/1 min between the following points:
Power supply terminals, I/O terminals,
IEC/EN 60730-1
Between the relay outputs,
IEC/EN 60601-1
Between the terminals and the DIN 43880 or equivalent control unit
>2 MΩ at 500 VDC between the following points:
Power supply terminals, I/O terminals,
IEC/EN 60730-1
Between the relay outputs
IEC/EN 60601-1
Between the terminals and the DIN 43880 or equivalent control unit
IEC/EN 60947-1
230 VAC version: 4 KV
IEC/EN 60730-1
24 VDC version: 0.8 KV
IEC/EN 60664-1
(Overvoltage category: 3, Degree of pollution: 3)
0: industrial mounting
IEC/EN 60730-1
II: mounting in casing for domestic use or flush-mounted in panel
IEC/EN 60730-1
Type 1C
IEC/EN 60730-1
Casing: 75 °C; active part: 125 °C
IEC/EN 60730-1
Class A
IEC/EN 60730-1
Independent mounting
- "CE" marked in relation to the Low Voltage Directive
(73/23/EEC + 93/68/EEC)
- Conforms with EMC Directive (89/336/EEC)
- UL/(c)UL (UL 508)
IEC/EN 60730-1
IEC/EN 60947-1
IEC/EN 60601-1
EN 50081-1/2
EN 50082-1/2
IEC/EN 61000-6-2
IEC/EN 60601-1-2
INSTALLATION MANUAL
-5 °C +55 °C
-40 °C +70 °C
Max. 95% RH, without condensation
IP 20
Absence of corrosive gas. Minimum dust
Self-extinguishing
Amplitude
Amplitude
Amplitude
09/2003- 9/13
Need help?
Do you have a question about the MILLENIUM II+ Series and is the answer not in the manual?