Dimensioned drawing housing IP54 ......................29 This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.
EU and in the individual countries have to be strictly followed. • The TOUSEK Ges.m.b.H. can not be held liable for any claims resulting from disregards of the laws and standards in force during the installation and operation.
General information Swing gate control unit ST 61 Control board features • suitable for swing gates with electromechanical operators • Safety system ARS (autom. reversal system) SWING X and SPIN 250, 230V (1 or 2 gate leafs) with inte- • operating mode: impulse, automatic or dead man mode grated sensor.
Terminal assignment Swing gate control unit ST 61 Warning • Before taking off the control cover, • The product is not suitable for installation in explosion- hazardous/explosive areas. the main switch must be turned off ! • The inside of the control unit is under tension when •...
Adjustments - overview Swing gate control unit ST 61 Programming buttons Adjustments - Overview • The adjustment (programming) of the operating parameters is carried out via four programming buttons and the text display. • Before you can start programming, select the language of the display. You can do this by pressing the + or - and choose the language for the menuas and press ENTER.
Page 7
The menu points courtyard lamp and control lamp will only appear on display if in menu „Additional module“ courtyard lamp/control lamp is selected. ENTER Swing gate control unit ST61 - 7 - tousek / E_ST61_07 / 06. 06. 2019...
Connections and adjustments Swing gate control unit ST 61 Warning • The product is not suitable for installation in explosion- • Before taking off the control cover, the hazardous areas. mains switch must be turned off! • An all-pole disconnecting mains switch with a contact •...
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation! - 9 - tousek / E_ST61_07 / 06. 06. 2019...
(contact: terminals 45/48) Safety active: to be selected, if outer photocell should be triggered. not active: to be selected, if outer photocell should not be triggered. - 10 - tousek / E_ST61_07 / 06. 06. 2019...
Page 11
Tousek RLS 620 as safety device transmitter receiver 12/24V 12/24V NC C NO 24Va.c. Important • Jumper J of transmitter and receiver has to be adjusted in the same way. - 11 - tousek / E_ST61_07 / 06. 06. 2019...
Page 12
radio edge TX310: to be selected if safety sensing edge (8,2kΩ) of main entrance edge 2 should be evaluated with the radio transmission system TX 310. • Connection and detailed information of radio transmission system TX 310 see according manual. - 12 - tousek / E_ST61_07 / 06. 06. 2019...
Page 13
• The photocell self-test can only be deactivated by selecting „not active“. • The deactivation of the self-test function is only permitted if the safety installations correspond to the category 3 ! - 13 - tousek / E_ST61_07 / 06. 06. 2019...
Page 14
• Attention: Before carrying out any connection works, the power supply of the gate facility has to be turned off. • Operators´ power supply and sensor cables as well as the capacitors must be connected to the ST 61 control unit acoording to the installation manual.
Page 15
CONNECTION of operators to control unit black Connection cable with left operator right operator blue colour or number to terminal to terminal brown brown blue or grey black green/yellow - 15 - tousek / E_ST61_07 / 06. 06. 2019...
pause time extension: an impulse in automatic operation restarts the pause time. If this menu point is chosen, the impulse suppression during opening is active at the same time. - 16 - tousek / E_ST61_07 / 06. 06. 2019...
Page 17
(HSK 1-term.50/52) Mode HSK 2 inside/outside outside active Limit tolerance Operating logic 20 (factory setting) 3–20 adjustable: indicates the tolerance in the end positions (low value = sensitive behaviour). - 17 - tousek / E_ST61_07 / 06. 06. 2019...
If the gate is closed, the pilot lamp expires illuminates in open position: Pilot lamp is illuminated as soon as the gate has reached end position open. - 18 - tousek / E_ST61_07 / 06. 06. 2019...
OPEN and CLOSE: locking via motorized locking bar in both end positions of the gate. only OPEN: locking via motorized locking bar only in open position. only CLOSE: locking via motorized locking bar only in closed position. - 19 - tousek / E_ST61_07 / 06. 06. 2019...
Page 20
LIGHT PERIPHERAL / ELECTRIC LOCK • Magnets are driven into the open and closed position of The series resistor (R) is for tousek the gate, the electric lock only in closed position. magnets GD 50 and GD 70.
Page 21
„T“ with tousek control units ST 51, motor ST 61, ST REX connection „ “ with foreign control units Limit switch closed, if the bolt is retracted DROPBOLT 2 - 21 - tousek / E_ST61_07 / 06. 06. 2019...
in this manual. Software version Diagnosis shows the software version and the operator type on the text display Serial number Diagnosis shows the serial number on the text display - 22 - tousek / E_ST61_07 / 06. 06. 2019...
(FE) as shown in the picture. entry mode switch. • For range extension an external antenna FK433 or FK868 • For programming of receiver please see manual for can be connected. radio receiver. - 23 - tousek / E_ST61_07 / 06. 06. 2019...
Putting into operation Swing gate control unit ST 61 Important: preparation works • Connect control panels, safety devices to the motor under the safety regulations in . Attention: if no stop switch is connected then the terminals 30/31 have to be bridged.
Page 25
$$$$$$$$$$$$$$$$ mainsafety edge2 $$$$$$$$$$$$$$$$ mainsafety edge2 $$$$$$$$$$$$$$$$ $$$$$$$$$$$$$$$$ active right (term. 50/53) adopt $$$$$$$$$$$$$$$$ mainsafety edge2 $$$$$$$$$$$$$$$$ not active adopt right (term. 50/53) $$$$$$$$$$$$$$$$ mainsafety edge2 $$$$$$$$$$$$$$$$ radio edge TX - 25 - tousek / E_ST61_07 / 06. 06. 2019...
Page 26
$$$$$$$$$$$$$$$$ motor right $$$$$$$$$$$$$$$$ change ? YES $$$$$$$$$$$$$$$$ delay right leaf $$$$$$$$$$$$$$$$ delay right leaf $$$$$$$$$$$$$$$$ $$$$$$$$$$$$$$$$ closing delay adopt $$$$$$$$$$$$$$$$ delay right leaf $$$$$$$$$$$$$$$$ opening delay - 26 - tousek / E_ST61_07 / 06. 06. 2019...
Page 27
• IMPORTANT: With 1 leaf gate installation, only the operator of the actually existing gate leaf must be activated in the main menu, the other one has to be disabled (deactivated) ! (In Main Menu: Left(Right) leaf / Motor / „Motor OFF“) - 27 - tousek / E_ST61_07 / 06. 06. 2019...
Troubleshooting guide Swing gate control unit ST 61 Error possible reason solution mains voltage missing control of mains voltage as well as of or fuse F1 defective fuse F1 no reaction after emitting a command Display: error stop button check if stop button is properly con-...
Dimensioned drawing housing IP54 Swing gate control unit ST 61 • dimensions in mm • Mounting dimensions (back side) We reserve the right to change dimensions and technical specifications without prior notice ! - 29 - tousek / E_ST61_07 / 06. 06. 2019...