Advertisement

Quick Links

User manual
UL-C10UA-W
Portable air conditioner
EN
Product images are for illustration purposes only. Actual product may vary.

Advertisement

Table of Contents
loading

Summary of Contents for Sharp UL-C10UA-W

  • Page 1 User manual UL-C10UA-W Portable air conditioner Product images are for illustration purposes only. Actual product may vary.
  • Page 3 10 11 13* 12 * - only for model UL-Y12EA-W T-OFF COOL OPER LOCK AUTO T-OFF COOL MODE OPER LOCK AUTO SWING TIMER Images are for guidance only...
  • Page 4 × 2 × 2 T-ON T-OFF AUTO SWING COOL OPER SLEEP LOCK AUTO SPEED HEAT ON/OFF MODE × 2 SWING SLEEP TIMER Images are for guidance only...
  • Page 5: Important Safety Instructions

    ,not covered under warrant and not supported by the manufacturer. • Compliance with national gas regulations have to be observed. Sharp will not be held responsible for personal injury or loss to property for the following: Important safety instructions 1.
  • Page 6: Operation Environment

    • If the equipment has been used for BUSINESS PURPOSES, please contact hazards occurring. your SHARP dealer who will inform you about take back. You might • Do not use an extension cord. be charged for the costs arising from take back. Small equipment (and Operation Environment: small quantities) might be taken back by your local collection facility.
  • Page 7: Contents Of The Box

    Contents of the Box NOTE ū Check if the accessories are available before installation. Refer to the pictures 6 on page 2. 1. Joint A (× 1) www.sharpconsumer.com/ www.sharpconsumer.com/ contact/ support/ 2. Rear Clip (× 1) 3. Heat Discharge Pipe (× 1) 4.
  • Page 8: Operation Of Control Panel

    Operation of Control Panel Remote control ON/OFF button Remote control buttons Pressing this button turns the air conditioner on and off. Refer to the pictures 4 on page 1. 1. ON/OFF + / - button 2. MODE Under cooling or heating mode, press “+” or “-” button to increase or 3.
  • Page 9: Care And Maintenance

    HEAT is selected by remote control, pressing ON/OFF button can't turn Temperature display switchover function on the air conditioner.) Under OFF status, press "-" button and "MODE" button simultaneously can switch between °C and °F. +/- button • Pressing + or - button once will increase or decrease set temperature Light function by 1°C.
  • Page 10: Troubleshooting

    Notice for recovery • Some of the packing items are recyclable materials. Please deal with them through your local recycling provider. • If you want to dispose the air conditioner, please contact local authority or consultant service center for the correct disposal method. Troubleshooting Before calling for service, please review the troubleshooting list below, since the problem may not be a main unit malfunction.
  • Page 11: Installation Precautions

    UL-C10EA-W UL-C12EA-W 0.13 Installation Precautions UL-Y12EA-W UL-C10UA-W WARNING! • Observe all governing codes and ordinances. • Do not use damaged or non-standard power cord. • Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents.
  • Page 12: Drain Water

    Install Power Cord Hooks Assemble the power cord hooks at the back of the unit with screws (the direction of power cord hooks is as shown in following figure). 2. Screw the drain connector to (included in the package) the spout by turning clockwise.
  • Page 13: Wiring Diagram

    Wiring Diagram groove joint A The electric schematic diagram are subject to change without notice. Please refer to the one on the unit. UL-C10EA-W UL-C12EA-W UL-C10UA-W 3. Lead the heat discharge pipe outdoors. ROOM TEMP. TUBE TEMP. RECEIVER WATER MOTOR SENSOR...
  • Page 14: Repair To Intrinsically Safe Components

    Check that cabling will not be subject to wear, corrosion, excessive The following checks shall be applied to installations using flammable pressure, vibration, sharp edges or any other adverse environmental refrigerants: effects. The check shall also take into account the effects of aging or •...
  • Page 15: Leak Detection Methods

    Leak detection methods recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be The following leak detection methods are deemed acceptable for all taken in case analysis is required prior to reuse of reclaimed refrigerant. It is refrigerant systems.
  • Page 16: Technical Specification

    When oil is drained from a system, it shall be carried out safely. Technical specification Model UL-C10UA-W Power Supply 220 – 240V AC, 50Hz Cooling Energy Efficiency Class...
  • Page 20 Sharp Consumer Electronics Poland sp. z o.o. Ostaszewo 57B, 87-148 Łysomice, Poland Made in China SDA/MAN/0197 www.sharpconsumer.eu...

Table of Contents