English
1. Wait until the SLIP light blinks. Then insert the check face up
with the right side of the check against the right side of the
paper guide as far as it will go. Be sure that the MICR
characters are on the right.
MICR
characters
on this side
face up
2. The printer will detect the check and start drawing it in. When
the printer starts drawing it in, let go of the check immediately.
When the printer ejects the check and the SLIP light starts
blinking again; remove the check by pulling it straight up; do
not pull it at an angle.

Cleaning the MICR Mechanism

Approximately every 12 months clean the MICR head with a
moistened cleaning sheet.
Use the following or an equivalent commercially available cleaning
sheet:
PRESAT brand (KIC) "CHECK READER CLEANING CARD."
Note:
Be sure not to use an adhesive cleaning sheet.
Follow the steps below:
1. Load a paper roll in the printer; turn off the power; then open
the paper roll cover and turn the power back on while holding
down the RELEASE button.
8 TM-H6000II User's Manual