Remove the old battery
1.
Remove the two screws holding the battery case to the back cover
(FIG. 3). Retain these screws, as they will be used to hold the new
battery.
2.
Carefully remove the battery from the back cover. Please dispose of the
battery in a proper fashion as required by municipal or federal regulations
Install the new battery
1.
Open the plastic bag containing the MVP-BP-5X kit, taking care not to
use sharp instruments near the battery itself.
2.
Remove the protective film on the battery case. DO NOT install the
battery without removing this film.
3.
Attach the new battery to the back cover, using the two screws used to
hold the previous battery to the cover.
Battery screws
MVP-BP-5X battery
FIG. 3
MVP-5200i back cover with battery installed
Reconnecting the battery to the device
1.
On the back cover, make sure that the battery connector wiring runs to
the right. Make sure that the excess battery wiring fits in the space to the
bottom left of the battery placement (FIG. 4). The battery wiring may be
looped around the support if necessary; make sure that the battery is not
crimped or damaged upon closure of the case.
Resistor location
FIG. 4
Path of excess battery wiring
2.
Make sure to seat fully the battery plug to the connector in the device
(FIG. 2). If fingers cannot be used, use a clean, nonconductive stick or
probe to seat the connectors.
NOTE: Special care must be taken to seat the battery plug so that it does
not damage or rub against the two resistors near the battery connector.
When connecting the battery, do not allow the battery plug to rub against
the circuit board.
3.
Reattach the back of the device, engaging the hook on the lower left of
the case (near the speaker) and using it to swing the back down into
place.
WARNING: When reassembling the device, take especial care not to
pinch or squeeze the connector wiring or the battery. Do not force the
back cover onto the device, as this can damage the device
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
.
Battery plug
Excess battery wiring path
MVP-BP-5X battery placement
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
4.
Insert the five screws and replace the rubber feet atop the two upper
screws, using the replacement rubber feet included in the Battery Pack
Kit (FIG. 5). Replace the bottom label over the three bottom screws, using
the replacement label included in the Battery Pack Kit.
.
Bottom screw
holes
Speaker
Front of MVP-5200i
FIG. 5
MVP-5200i back plate installation
NOTE: The three bottom screws are shorter than the top two screws. The
screws must be re-assembled in their original location or the device can be
damaged during reassembly.
5.
Restart the device to confirm that the new battery is functioning correctly.
For more information on battery replacement and installation, please refer to
the MVP-5200i Modero Touch Panel Operator/Reference Guide, available from
www.amx.com.