D
E
B
5) Press the reset button D on the main screen
to return to the origin.
6) Press in the same way as in step 2) to en-
ter the tension setting screen, and enter the
tension setting value confirmed in step 3) into
tension 1E.
Set the default tension B to "1".
30
Thread tension 1 at the start of sewing : 30
1. The default tension and tension
1 settings are valid from 1 to
100 (integers only).
2. To set the default tension, just
check the appropriate tension
by trial sewing, and set tension
1 during production.