6.
T
D
ECHNICAL
ATA
This equipment is designed for failsafe operation, meeting the stringent requirements for safe operation.
It is in accordance to EU's demands to CE-label the equipment.
6.1
G
S
ENERAL
PECIFICATION
* Temperature Range:
* Shock Resistance:
* Cable
6.2
C
, CU212-1S
ONTROL UNIT
* Power Supply:
* Power Consumption:
* Outputs:
* Optional inputs
* Connections:
* Indicators:
* Housing:
* Dimensions:
* Weight:
6.3
H
, CB212-1S F
ANDSWITCH
* Controls
* Operation
* Connections
* Housing:
* Dimensions:
* Weight:
D
RCS AS
ELTA
User and Installation Manual for DE212-1S Wired Deadman
Operational and storage: -25 to +65º C.
2 m free-fall on concrete floor.
Coiled, 14m length fully stretched. 2 cores, cross area 0,75mm2.
11 to 35 VDC. Voltage above 35VDC shuts down the receiver.
Standby: 22 mA.
Semiconductor output. Temperature and overload protected. Output voltage
is equal to power input; 12/24 VDC. Each output, max 3,5A
total load, 5A. Fused inside by 5A slow blow Auto fuse.
* Deadman output. Active when deadman switch is operated.
* Warning light output, active during operation of the deadman
* Beeper warning output
* STOP output. When control unit is powered, this output is active, output
is12/24V. When STOP is detected, this output is switched off.
*The CU212-1S is programmed to operate with or without a none failsafe
handswitch. To select a none failsafe handswitch, set SW2-1 to OFF. See
chapter 2.
* Deadman override, low input activates the override function
* External STOP, low input actives STOP of deadman function.
Screw terminal on PCB connector.
Green light diode that indicates power on.
Yellow light diode that indicates active deadman.
ABS polycarbonate, class IP52.
L:160 mm, W: 80 mm, D: 60 mm.
0.7 kg
AILSAFE
Two pushbuttons; Deadman and STOP.
Deadman push button is operated by handle.
STOP is operated when handle is opened and STOP button pushed.
Screw terminals on PCB inside housing.
Polyamid 6, class IP65.
Length: 170 mm, diameter: 40 mm.
0.3 kg