Safety instructions for installation
Risk of damage from incorrect installation.
Incorrect installation can cause damage to the SmartLine appliance.
The SmartLine appliance must only be installed by a suitably qualified and
competent person.
Risk of electric shock!
Incorrect connection to the power supply may result in an electric shock.
The SmartLine appliance must be connected to the electrical supply by a
qualified person only.
Damage from falling objects.
Take care not to damage the SmartLine appliance when fitting wall units or a
rangehood above it.
Fit the wall units and the rangehood before the SmartLine appliance.
The veneer or laminate coatings of worktops (or adjacent kitchen
units) must be treated with 100 °C heat-resistant adhesive which will
not dissolve or distort. Any splashbacks must be of heat-resistant
material.
The SmartLine appliance must not be installed over a fridge,
fridge-freezer, freezer, dishwasher, washing machine, washer-dryer
or tumble dryer.
This SmartLine appliance must not be installed above ovens
unless these have a built-in cooling fan.
After installation, the mains connection cable of the SmartLine
appliance must not come into contact with any moving kitchen
component (e.g. a drawer) or be subject to mechanical loads which
could damage it.
Carefully observe the safety clearances listed on the following
pages.
10878121-02
Installation

Advertisement

loading

Summary of Contents for Miele SmartLine CS 7612 FL

  • Page 1 *INSTALLATION* 10878121-02 Installation Safety instructions for installation  Risk of damage from incorrect installation. Incorrect installation can cause damage to the SmartLine appliance. The SmartLine appliance must only be installed by a suitably qualified and competent person.  Risk of electric shock! Incorrect connection to the power supply may result in an electric shock.
  • Page 2: Safety Distances

    *INSTALLATION* 10878121-02 Installation Safety distances Safety distance above the SmartLine element The safety distance specified by the manufacturer of the cooker hood must be maintained between the SmartLine element and the cooker hood above it. If combustible objects are installed above the SmartLine element (e.g.
  • Page 3 *INSTALLATION* 10878121-02 Installation Safety distances to the sides and Minimum safety distance underneath back of the appliance the SmartLine appliance The SmartLine appliance should To ensure proper ventilation of the preferably be installed with plenty of SmartLine appliance, a minimum safety space on the right and left.
  • Page 4 *INSTALLATION* 10878121-02 Installation Tiled worktop Installation notes – surface-mounted Sealing between the SmartLine appliance and the worktop Grout lines  and the hatched area underneath the SmartLine appliance frame must be smooth and even. If they are not, the SmartLine appliance will not sit flush with the worktop and the sealing strip underneath the top part of The SmartLine appliance and...
  • Page 5 *INSTALLATION* 10878121-02 Installation Installing several SmartLine appliances The gaps between the individual SmartLine appliances must be sealed with a silicone sealant that is heat- resistant to at least 160 °C. With flush- fit installation, the gap between the SmartLine appliance(s) and the worktop must also be sealed with a silicone sealant that is heat-resistant to at least 160 °C.
  • Page 6 *INSTALLATION* 10878121-02 Installation Worktop cut-out – surface-mounted ß R 4...
  • Page 7 *INSTALLATION* 10878121-02 Installation Installation with a downdraft extractor Sample combinations Number x width [mm] Dimension  B Cooking Downdraft [mm] appliances extractor 1 x 378 1 x 120 2 x 378 1 x 120 1 x 378 2 x 120 1226 1 x 620 3 x 378 2 x 120 1365 2 x 378 2 x 120 1607 1 x 620 4 x 378 2 x 120 1746 1 x 620 2 x 120...
  • Page 8 *INSTALLATION* 10878121-02 Installation Installation without a downdraft extractor Sample combinations Number x width [mm] Dimension B [mm] Cooking appliances 1 x 378 2 x 378 1 x 378 1 x 620 3 x 378 1121 2 x 378 1363 1 x 620 4 x 378 1502 2 x 378 1554 1 x 800 2 x 378 1680 1 x 936...
  • Page 9 *INSTALLATION* 10878121-02 Installation Spacer bars – surface-mounted If you are installing several appliances, you must fit spacer bars between them. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL. Installing 3 appliances and 2 spacer bars...
  • Page 10 *INSTALLATION* 10878121-02 Installation Installation dimensions – Surface-mounted All dimensions in this instruction booklet are given in mm. a Front b Mains connection cable, L = 2,000 mm...
  • Page 11 *INSTALLATION* 10878121-02 Installation Wooden worktops Installation – surface-mounted Preparing the worktop  Create the worktop cut-out. Remember to maintain the minimum safety distances (see "Installation – Safety distances").  Seal the cut surfaces of wooden worktops with a suitable sealant to avoid swelling caused by moisture.
  • Page 12 *INSTALLATION* 10878121-02 Installation Installing the SmartLine appliance Unsuitable sealant can damage natural stone.  Stick the supplied sealing strip under the edge of the SmartLine appliance. For natural stone worktops and Do not apply the sealing strip under natural stone tiles, only use silicone tension.
  • Page 13 *INSTALLATION* 10878121-02 Installation Natural stone worktops Installation notes – flush-fit The SmartLine appliance is set directly in the cut-out. Flush-fit installation is only possible in natural stone (granite, marble), solid Solid wood worktops, tiled worktops, wood and tiled worktops. For glass worktops installation in worktops made of other The SmartLine appliance is set on a...
  • Page 14 *INSTALLATION* 10878121-02 Installation Installing several SmartLine appliances The gaps between the individual SmartLine appliances must be sealed with a silicone sealant that is heat- resistant to at least 160 °C. With flush- fit installation, the gap between the SmartLine appliance(s) and the worktop must also be sealed with a silicone sealant that is heat-resistant to at least 160 °C.
  • Page 15 *INSTALLATION* 10878121-02 Installation Worktop cut-out – flush-fit ß R 4 + 0,5 * + 0,5 * Natural stone worktop Wooden worktop + 0.5  mm with CS 7611 FL...
  • Page 16 *INSTALLATION* 10878121-02 Installation Installation with a downdraft extractor Sample combinations Number x width [mm] Dimension A Dimension B [mm] [mm] Cooking Downdraft appliances extractor 1 x 378 1 x 120 2 x 378 1 x 120 1 x 378 2 x 120 1250 1226 1 x 620 3 x 378 2 x 120 1389 1365 2 x 378 2 x 120 1631 1607 1 x 620 4 x 378 2 x 120 1770 1746 1 x 620...
  • Page 17 *INSTALLATION* 10878121-02 Installation Installation without a downdraft extractor Sample Number x width Dimension A Dimension B combinations [mm] [mm] [mm] Cooking appliances 1 x 378 2 x 378 1 x 378 1006 1 x 620 3 x 378 1145 1121 2 x 378 1387 1363 1 x 620 4 x 378 1526 1502 2 x 378 1567 1543 1 x 800 2 x 378 1703 1679 1 x 936...
  • Page 18 *INSTALLATION* 10878121-02 Installation Spacer bars – flush-fit If you are installing several appliances, you must fit spacer bars between them. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL. Installing 3 appliances and 2 spacer bars...
  • Page 19 *INSTALLATION* 10878121-02 Installation Installation dimensions – Flush-fit All dimensions in this instruction booklet are given in mm. a Front b Mains connection cable, L = 2,000 mm c Stepped cut-out (for detailed illustrations, see “Installation – Worktop cut-out – flush-fit”) d 12 mm wooden frame (not supplied, for detailed illustrations, see “Installation – Worktop cut-out –...
  • Page 20 *INSTALLATION* 10878121-02 Installation Wooden worktops Installation – flush-fit Preparing the worktop  Create the worktop cut-out. Remember to maintain the minimum safety distances (see "Installation – Safety distances").  Seal the cut surfaces of wooden worktops with a suitable sealant to avoid swelling caused by moisture.
  • Page 21 *INSTALLATION* 10878121-02 Installation Installing the SmartLine appliance  Stick the supplied sealing strip under the edge of the SmartLine appliance. Do not apply the sealing strip under tension.  Feed the mains connection cable down through the worktop cut-out.  Position the SmartLine appliance in the worktop cut-out.
  • Page 22: Electrical Connection

    The connection data is given on the and repairs can be dangerous to data plate. Please ensure this users. information matches the household Miele cannot be held liable for mains supply. damage or injury (e.g. electric shock) caused by unauthorised installation, Residual current device...