Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
Delta DVP PLC
A. HMI factory settings
Baud rate: 9600, 7, Even, 1.
Controller station number: 1.
Control area/status area: D0 / D10.
B. Definition of controller Read/Write address
Registers
Register Type
X_Data
Y_Data
M_Data
S_Data
T_Register
C_Register
D_Register
HC_Register
NOTE
1) (W) is "Word".
2) (DW) is "Double Word".
3) X_Data / Y_Data / M_Data / S_Data: Address must be 0 or the multiple of 16.
Contacts
Contact type
X_Data
Y_Data
M_Data
S_Data
T_Coil
C_Coil
1-12
Format
Xn
n: 0 ~ 360(octal)
Yn
n: 0 ~ 360(octal)
Mn
n: 0 ~ 1520, 1536 ~ 4080
Sn
n: 0 ~ 1008
Tn
n: 0 ~ 255
Cn
n: 0 ~ 199
Dn
n: 0 ~ 4095, 4096 ~ 9999
Cn
n: 200 ~ 255
Format
Xn
N/A
Yn
N/A
Mn
N/A
Sn
N/A
Tn
N/A
Cn
N/A
Read/Write Range
Word No.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Read/Write Range
Word No.
n: 0 ~ 377(octal)
n: 0 ~ 377(octal)
n: 0 ~ 1520, 1536 ~ 4080
n: 0 ~ 1023
n: 0 ~ 255
n: 0 ~ 255
Revision January, 2008, Doc. Name: 2007PDD23000007