8) Byte 84-91: Date code.
9) Byte 95: Check sum of bytes 64-94.
10) Byte 128 to 255 had been set hex 00.
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
#
Address
Bytes
00-01
2
Temp High Alarm
02-03
2
Temp Low Alarm
04-05
2
Temp High Warning
06-07
2
Temp Low Warning
08-09
2
Voltage High Alarm
10-11
2
Voltage Low Alarm
12-13
2
Voltage High Warning
14-15
2
Voltage Low Warning
16-17
2
Bias High Alarm
18-19
2
Bias Low Alarm
20-21
2
Bias High Warning
22-23
2
Bias Low Warning
24-25
2
TX Power High Alarm
26-27
2
TX Power Low Alarm
28-29
2
TX Power High Warning
30-31
2
TX Power Low Warning
32-33
2
RX Power High Alarm
34-35
2
RX Power Low Alarm
36-37
2
RX Power High Warning
38-39
2
RX Power Low Warning
40-45
16
Reversed
56-91
36
External Calibration Constants
92-94
3
Reversed
95
1
Checksum
96-97
2
Real Time Temperature
98-99
2
Real Time Supply Voltage
100-101
2
Real Time Tx Bias Current
102-103
2
Real Time Tx Optical Power
104-105
2
Real Time Rx Received Power
106-109
4
Reserved
110
1
Optional Status/ Control Bits
111
1
Reserved
112-119
8
Optional Set of Alarm and Warning
Notes:
1) T
: Case Operating temperature.
C
2) I
: Operating current at room temperature. The min. setting current is 0 mA.
OP
3) P: Operating optical power of transmitter at room temperature.
4) P
: Overload optical power of receiver.
0
DELTA ELECTRONICS, INC.
Name
11
Value (Dec.)
Unit
T
(MAX.)+15
C
T
(MIN.)
C
T
(MAX.)+10
C
T
(MIN.)+10
C
Vcc+5%
Volt
Vcc-5%
Vcc+3%
Vcc-3%
I
*2+35
mA
OP
I
-13
OP
I
*2+30
OP
I
–8
OP
P+3
dBm
P-3
P+2
P-2
P
+3
dBm
0
P
-2
S
P
+2
0
P
S