Versa Drawer™ Refrigeration Units
RECEIVING AND INSPECTING THE
EQUIPMENT
Even though most equipment is shipped crated, care
should be taken during unloading so the equipment is
not damaged while being moved into the building.
1. Visually inspect the exterior of the package and
skid or container. Any damage should be noted and
reported to the delivering carrier immediately.
2. If damaged, open and inspect contents with carrier.
3. In the event that the exterior is not damaged, yet
upon opening, there is concealed damage to the
equipment notify the carrier. Notification should be
made verbally as well as in written form.
NOTE: This manual covers standard units only. If
you have a custom unit, consult the technical service
department.

SERIAL NUMBER

The serial number is located on the data plate mounted
inside of Drawer 1. Always have the serial number of
your unit available when calling for parts or service.
SPECIFICATIONS (115V/60Hz)
Freestanding Models
Model
L
50"
18650VDR
127.0cm
50"
18650VDL
127.0cm
82"
18682VDR
208.3cm
82"
18682VDL
208.3cm
84"
F2984VDR
213.4cm
84"
F2984VDL
213.4cm
Component Crafted Models
Model
L
50"
F18VD50
127.0cm
82"
F18VD82
208.3cm
84"
F17VD84
213.4cm
Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210
# of
D
H
Drawers
31.5"
34"
2
80.0cm
86.4cm
31.5"
34"
2
80.0cm
86.4cm
31.5"
34"
4
80.0cm
86.4cm
31.5"
34"
4
80.0cm
86.4cm
31.5"
26"
2
80.0cm
31.5"
26"
2
80.0cm
# of
D
H
Drawers
31.5"
36"
2
80.0cm
91.4cm
31.5"
36"
4
80.0cm
91.4cm
31.5"
36"
2
80.0cm
91.4cm
4. Request an inspection by the shipping company
of the damaged equipment. This should be done
within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs
or casters are not bent.
6. Be sure to inspect the compressor compartment
housing and visually inspect refrigeration package.
Be sure lines are secure and base is still intact.
7. Freight carriers can supply the necessary damage
forms upon request.
8. Retain all crating material until an inspection has
been made or waived.
Serial Number Location
Volts
HZ
Amps
HP
115
60
6.0
1/3
115
60
6.0
1/3
115
60
12.0
(2) 1/3
115
60
12.0
(2) 1/3
115
60
6.0
1/3
115
60
6.0
1/3
Volts
HZ
Amps
HP
115
60
6.0
1/3
115
60
12.0
(2) 1/3
115
60
6.0
1/3
Ref.
Ship Weight
Plug
Charge
lbs.
5-15P
30oz.
520
5-15P
30oz.
520
5-15P
(2) 30oz.
720
5-15P
(2) 30oz.
720
5-15P
30oz.
520
5-15P
30oz.
520
Ref.
Ship Weight
Plug
Charge
lbs.
5-15P
30oz.
520
5-15P
(2) 30oz.
720
5-15P
30oz.
620
3

Advertisement

Table of Contents
loading

Table of Contents