  • Page 1 MAP/100P RAID System Recovery MAP/100P RAID System Recovery - 1 Issue 2 November 1999...
  • Page 2 To identify a failed hard disk drive contact your remote maintenance center. MAP/100P - Front View MAINTENANCE USE ONLY FAN FAULT DISK ACTIVITY LATCH RELEASE POWER ON P/S FAULT FAN FAULT FAN FAULT mpixf10p LJK 031799 Issue 2 MAP/100P RAID System Recovery - 2 November 1999...
  • Page 3 The system should automatically rebuild the hard disk drive. The hard disk drive LED will flash to indicate the rebuild activity. If the system does not automatically rebuild the hard disk drive, contact your remote maintenance center. Procedure completed. Issue 2 MAP/100P RAID System Recovery - 3 November 1999...
  • Page 4 If only one drive, or no drives, is marked DED, exit the utility by pressing ESCAPE. The system should successfully boot. CAUTION: Do not complete Step 4 on the first hard disk drive to have failed. Continue, press PAGE DOWN. Issue 2 MAP/100P RAID System Recovery - 4 November 1999...
  • Page 5 If both cables are properly connected, contact your remote maintenance center. Select: Repeat Step 4 and Step 5 for each hard disk drive, other than the first hard disk drive to fail, marked DED. Press ESCAPE. Continue, press PAGE DOWN. Issue 2 MAP/100P RAID System Recovery - 5 November 1999...
  • Page 6 Reboot the system. The system will report errors related to the failure. The system should be fully operational. If the system is not fully operational, restore the system. Procedure completed. Issue 2 MAP/100P RAID System Recovery - 6 November 1999...
  • Page 7 Replace the incorrectly removed hard disk drive. Remove the failed hard disk drive. Place the empty hard disk drive assembly bracket back into the MAP/100P. NOTE: NOTE: Do not install the replacement hard disk drive at this point. Reboot the system.
  • Page 8 Do you want to continue? Select: Press ESCAPE. Reboot the system. The system will report errors related to the failure. The system should be fully operational. Continue, press PAGE DOWN. Issue 2 MAP/100P RAID System Recovery - 8 November 1999...
  • Page 9 The system should automatically rebuild the hard disk drive. The hard disk drive LED will flash to indicate the rebuild activity. If the system does not automatically rebuild the hard disk drive, contact your remote maintenance center. Procedure completed. Issue 2 MAP/100P RAID System Recovery - 9 November 1999...
  • Page 10 RAID Controller Settings Main Menu RAID Controller Settings Main Menu Main Menu Automatic Configuration New Configuration View/Update Configuration Rebuild Initialize System Drive Consistency Check Tools Select DAC960 Advanced Functions Issue 2 MAP/100P RAID System Recovery - 10 November 1999...
  • Page 11 14 Power supply fault LED POWER ON P/S FAULT FAN FAULT 15 Power On LED FAN FAULT 16 Hard disk drive activity LEDs 17 Fan fault LED 18 SCSI terminating resistor mpixf10p LJK 031799 Issue 2 MAP/100P RAID System Recovery - 11 November 1999...