NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
ProFitter
Operating Instructions and Parts Manual
TM
ProFitter
Portable Oil-Fired Heaters
IMPORTANT : Do not store kerosene
over summer months for use during
next heating season. Using old fuel
could damage heater.
4. Reinstall fuel cap. Properly dispose
of old and dirty fuel. (For Models
KFA50PF, KFA75PF Only)
5. Reinstall Fuel Drain Bolt to Fuel tank
and tighten firmly using 3/4" socket or
adjustable wrench.
(For Models KFA125PF, KFA170PF,
KFA210PF Only)
Fuel Drain Bolt
Figure 12 - Drain Bolt
6. Store heater in dry well ventilated
area. Make sure storage place is
free of dust and corrosive fumes.
7. Store the heater in the original box
with the original packing material
and keep the USER'S MANUAL
with the heater.
- Make sure storage place is free of dust
and corrosive fumes.
- Store the heater in the original box
with the original packing material and
keep USER'S MANUAL with heater.
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com
TM

Maintenance

WARNING
or while hot!
USE ORIGINAL EQUIPMENT REPLACE-
MENT PARTS. Use of third-party or
other alternate components will void
warranty and may cause unsafe
operating conditions.
FUEL TANK
Flush every 200 hours of operation or as
needed (See Long-term Storage, page 7).
Seal
AIR INTAKE FILTER
WASH AND DRY WITH SOAP AND
WATER EVERY 500 HOURS OF
OPERATION, OR AS NEEDED.
- Remove screws along each side of
heater using medium Phillips
screwdriver.
- Lift off upper shell.
- Remove fan guard.
- Wash or replace air intake filter.
- Reinstall fan guard and upper shell.
Figure 13 – Air Filter Access
AIR OUTPUT FILTER, LINT FILTER
REPLACE EVERY 500 HOURS OF
Never service heater
while it is plugged in
OPERATION OR ONCE A YEAR
- Remove upper shell and fan guard
- Turn air pressure gauge counter-
- Remove end filter cover screws using
- Remove end filter cover.
- Replace air output and lint filter.
- Reinstall end filter cover and air
- Reinstall fan guard and upper shell.
FAN BLADES
CLEAN EVERY SEASON OR AS NEEDED
Screw
Lint Filter
Upper Shell
Figure 14 – Filter Assembly
Air Intake Filter
- Remove upper shell (See Air Intake
Fan Guard
- Use M6 Allen wrench to loosen set
- Slip fan blade off motor shaft.
- Clean fan blade using soft cloth
- Dry fan blade thoroughly.
- Reinstall fan blade to motor shaft.
- Place fan blade hub flush with end of
8
KFA50PF, KFA75PF, KFA125PF,
KFA170PF and KFA210PF
(See Air Intake Filter Figure 13).
clockwise and remove.
medium Phillips screwdriver.
pressure gauge.
Air Output
Filter
End Filter
Cover
Filter).
screw which holds fan blade to motor
shaft.
moistened with kerosene or solvent.
motor shaft.
Screw
Air Intake
Filter
Air Pressure Gauge