Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
ProFitter
Oil-Fired Heaters
Description
ProFitter
Models KFA50PF, KFA75PF, KFA125PF, KFA170PF and KFA210PF
TM
heaters are 50,000 to 210,000 BTU/Hr heaters.
These heaters use 1-K Kerosene (see Operation section for alternative fuels) for
combustion, and electricity to run the fan. It is primarily intended for temporary
heating of well ventilated buildings under construction, alteration, or repair. This
heater may be used in agricultural, industrial and com-mercial environments.
Specifications
ELECTRICAL SPECIFICATIONS
Electrical
Model
Input
120V, 60 Hz
KFA50PF
120V, 60 Hz
KFA75PF
120V, 60 Hz
KFA125PF
120V, 60 Hz
KFA170PF
120V, 60 Hz
KFA210PF
GENERAL SPECIFICATIONS
Type of
Model
Fuel
1-K Kerosene
KFA50PF
1-K Kerosene
KFA75PF
1-K Kerosene
KFA125PF
1-K Kerosene
KFA170PF
1-K Kerosene
KFA210PF
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1
Assembly . . . . . . . . . . . . . . . . . . . . . . . 4-5
Operation . . . . . . . . . . . . . . . . . . . . . . 5-8
. . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Ventilation . . . . . . . . . . . . . . . . . . . . . . 7
TM
Amperage
Fuse
1.6
125V/8 amp
1.6
125V/8 amp
2.5
125V/8 amp
3.2
125V/8 amp
3.7
125V/8 amp
Pump
Input Rating
Pressure
50,000 BTU/Hr
3.8 PSI
75,000 BTU/Hr
3.8 PSI
125,000 BTU/Hr
5.5 PSI
170,000 BTU/Hr
6.5 PSI
210,000 BTU/Hr
8.5 PSI
Page
Repair Parts Illustration Models
Repair Parts List Models
KFA170PF
Repair Parts Illustration Model
. .
Repair Parts List Model
KFA210PF
. .
Repair Parts List, Wheels and
Handles . . . . . . . . . . . . . . . . . . . . . . . . . 18
Introduction
Please read this USER'S MANUAL
carefully. It will show you how to
Spark Plug Gap
.140" (3.5mm)
.140" (3.5mm)
.140" (3.5mm)
.140" (3.5mm)
.140" (3.5mm)
Fuel Tank
Fuel
Capacity
Consumption
5.0 Gallons
.38 Gal/Hr
5.0 Gallons
.57 Gal/Hr
10.0 Gallons
.95 Gal/Hr
13.0 Gallons
1.3 Gal/Hr
13.0 Gallons
1.6 Gal/Hr
. .
. . . . . . . .
. . . . . . .
. . . . . . .
. .
. . .
. . . .
. .
. . . . . .
. . . . . .
14-15
. . . .
. . . . . . . . . . . . . . . . . .
. .
. .
. . . .
. . . . . . . . . . . . . .
KFA50PF, KFA75PF,
KFA125PF, KFA170PF and KFA210PF
Figure 1 - Models
KFA50PF & KFA75PF
Figure 2 - Model KFA125PF
Figure 3 - Models
KFA170PF & KFA210PF
Size
L x W x H (Inches)
32 x 11
/
x 16
/
3
3
4
4
32 x 11
/
x 16
/
3
3
4
4
36
/
x 2
1
/
x 24
/
1
1
6
10
2
41
/
x 23
/
x 26
8
1
10
10
41
/
x 23
/
x 26
8
1
10
10
assemble, maintain and operate this
heater safely and efficiently to obtain
the full benefits of its many features.
14
Consumer: Retain these instructions
for future reference.
Unpacking
1. Remove all packing items applied to
heater for shipment.
16
2. Remove all items from carton.
3. Check all items for shipping damage. If
17
heater is damaged, promptly inform
dealer where you purchased heater.
Weight
Lbs. (kg)
26.9(12.2)
26.9(12.2)
51.4(23.3)
10
/
57.3(26.0)
1
10
/
59.5(27.0)
1
10
IMKFAPF-HDW