Installation manual R32 Split series – Domestic hot water tank https://daikintechnicaldatahub.eu Installation manual EKHWET90BAV3 English R32 Split series – Domestic hot water tank EKHWET120BAV3...
Configuration wizard: Language ......... 14 Daikin website (publicly accessible). 7.2.2 Configuration wizard: Time and date ......14 ▪ The full set of latest technical data is available on the Daikin 7.2.3 Configuration wizard: System ........14 Business Portal (authentication required).
Make sure installation, servicing, maintenance and repair cable. comply with instructions from Daikin and with applicable INFORMATION legislation and are executed ONLY by authorised persons. Details of type and rating of fuses, or rating of circuit Opening and closing the unit (see "4.2 Opening and closing the...
(example: open Make sure installation, servicing, maintenance and repair flames, an operating gas appliance or an operating electric comply with instructions from Daikin and with applicable heater). legislation and are executed ONLY by authorised persons. WARNING...
4 Unit installation 4.1.3 Installation patterns Depending on the type of room in which you install the indoor unit, different installation patterns are allowed: Room type Allowed patterns Living room, kitchen, garage, attic, basement, storage room 1, 2 Technical room (i.e. room that is NEVER occupied by persons) 1, 2, 3 PATTERN 1 PATTERN 2...
Page 7
4 Unit installation PATTERN 2 PATTERN 2: Conditions ventilation openings If you want to take advantage of the floor area of the adjacent room, you must provide 2 openings (one at the bottom, one at the top) between the rooms to ensure natural ventilation.
Page 8
4 Unit installation Tables for PATTERN 1 and 2 Table 1: Minimum floor area Take the following into account: • For intermediate floor areas, use the column with the lower value. Example: If the floor area is 1.7 m², use the column of 1.65 m². •...
4 Unit installation (dm²) – In case of Refrigerant charge=2.6 kg nv-min Release height (m) Floor area of room A (m²) [! NOT room A + room B !] 2,00 4,00 6,00 8,00 10,00 12,00 14,00 2.45 2.65 1.85 2.05 2.25 PATTERN 3 PATTERN 3 is only allowed for installations in technical rooms (i.e.
5 Piping installation 3 Reinstall the bottom cover. NOTICE When closing the indoor unit cover, make sure that the tightening torque does NOT exceed 2.94 N•m. Mounting the indoor unit 4.3.1 To install the indoor unit 1 Install 2 plugs into the wall and insert (but not completely) 2 bolts with washers Ø8 mm into the plugs.
6 Electrical installation Preparing water piping NOTICE A pressure relief valve (field supply) with an opening NOTICE pressure of maximum 7 bar (=0.7 MPa) must be installed on the domestic cold water inlet connection in accordance In case of plastic pipes, make sure they are fully oxygen with the applicable legislation.
6 Electrical installation CAUTION To guarantee the unit is completely earthed, ALWAYS connect the booster heater power supply and the earth cable. Connect the booster heater power supply as follows: 1 2 3 Interconnection cable (=main power supply) Q1DI 6.3.2 To connect the booster heater power supply Booster heater...
7 Configuration ▪ Restart the configuration wizard. If the system is already configured, you can restart the configuration wizard. To restart the configuration wizard, Installer settings > Configuration wizard. To access Installer settings, see commands" [ 4 13]. "7.1.1 To access the most used ▪...
7 Configuration Configuration wizard Advanced user 1234 After first power ON of the system, the user interface starts a configuration wizard. Use this wizard to set the most important initial settings for the unit to run properly. If required, you can afterwards configure more settings.
7 Configuration set the exact heater capacity and this will lead to more accurate The tank will heat up until the storage comfort temperature has energy data. The capacity of the booster heater installed in the been reached. It is the higher desired temperature when a storage domestic hot water tank is 1,2 kW.
7 Configuration Weather-dependent curve ambient temperatures too cold, raise the slope so that the tank temperature is heated increasingly more at decreasingly lower To be able to compensate for differences in temperature, the unit ambient temperatures. relies on its weather-dependent curve. This curve defines how much the target temperature of the tank must be at different outdoor ▪...
7 Configuration To define the setpoint mode You feel … Fine-tune with slope and offset: To use the weather-dependent curve, you need to define the correct setpoint mode: At regular outdoor At cold outdoor Slope Offset temperatures … temperatures … Go to setpoint mode …...
The correct pipe size is installed and the pipes are commissioning instructions in this chapter, a general properly insulated. commissioning checklist is also available on the Daikin Business Portal (authentication required). There is NO water leak inside the indoor unit.
9 Hand-over to the user 4 Select OK to confirm. Result: The actuator test run starts. It stops automatically when ready (±30 min). To stop the test run manually: — 1 In the menu, go to Stop test run. 2 Select OK to confirm. Possible actuator test runs ▪...
10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit 3D138207 Domestic hot water –...
10 Technical data 10.2 Wiring diagram: Indoor unit See the internal wiring diagram supplied with the unit (on the inside of the indoor unit switch box cover). The abbreviations used are listed below. Legend Note 1: Connection point of the Note 1: Connection point of the power supply for the BSH should power supply for the booster...
Page 22
10 Technical data Electrical connection diagram For more details, please check the unit wiring. STANDARD PART Power supply OUTDOOR UNIT Only for normal power supply installation 3 core unit power supply: 230 V + earth X1M: L-N-earth Only for preferential kWh rate power supply installation unit preferential kWh rate power supply: 3 core 230 V + earth...