Address
Default
0467
00
0469
07
046A
05
28.3.3. Battery Parameters
Address
Default
0F04
9A
28.3.4. Default Audio-Parameters
Name
Country
Setting
FactoryLanguageSetting x
MaxDifitsToMatch
MinDigitsToMatch
Name
LowVoltage
0A
German
Type
Description
D
Factory setting for language:
00 = English
01 = Spanish
02 = French
03 = Italian
04 = Dutch
05 = Turkish
06 = Hungarian
07 = Portuguese
08 = Polish
09 = Command
0A = German
x
D
Valid values: 01 - FF
Digits above this value will not be
evaluated, when matching.
x
D
Valid values: 01 - FF (-Must be lower tha
MaxDigitsToMatch).
-If all digits of one of the numbers match
completely,
-with at least this number of digits, we h
a match.
(-Or if they match completely with less
digits, we also have match.)
Type
A
Voltage on which to start battery low-
indication.
The voltage has to be measured under th
value for
8 seconds before the handset start
signaling low battery.
LowVoltage[eeprom]=[ADC-steps]=
LowVoltage[mV](14.35[mV/step])
67
Description