8
Priming Parameters
Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Priming Parameters
All priming settings can be edited and set from this screen. Tap a specific setting on the right-side of the screen to edit.
1- Enabled/Disabled: ENABLED allows the pump to detect whether
or not the system is properly primed for pump startup.
If prime is not detected the pump will enter a priming cycle,
based on the settings below.
2− Priming Speed: Set the speed the pump will run during a priming
cycle.
3− Max Priming Duration: Set the maximum amount of time the
pump will attempt to prime.
If the pump does not achieve prime during this time a priming error
will display and the pump will stop.
4− Priming Range: Set the sensitivity of pump prime detection.
Lower settings require higher flow to detect a successful prime.
5− Priming Delay: Set the amount of time the pump remains at
priming speed before transitioning to the run program.
6− Loss of Prime: ENABLED allows the pump to detect low-flow or
no-flow situations while running.
If a loss of prime is detected the pump will pause and attempt to
prime, based on the settings above. If priming is successful the
pump will continue programmed operation.

Limits Parameters

Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Limits Parameters
Set and edit pump speed, flow and pressure limits. These settings will ensure your pump does not operate
outside of the programmed parameters.
1- Minimum/Maximum Speed: Set the absolute minimum and maximum
speeds the pump will be allowed to run. Pump run speed will
never run under or over these two settings.
2− Minimum/Maximum Flow: Set the absolute minimum and
maximum flow rate the pump will be allowed. Pump GPM will
never fall under or exceed these two settings.
Note: These minimum and maximum flow rates only apply to
Flow Programs. To apply these settings to Speed Programs as
well, the next setting (Flow Limit - Speed Programs) must be
enabled.
3− Flow Limit (Speed Programs): Enable or disable minimum and
maximum flow rate limits for Speed Programs.
4− Max Pressure: Set the absolute maximum system pressure the
pump will be allowed to produce. Pump system pressure will never
exceed this setting.
Note: The maximum pressure setting only applies to Flow
Programs. To apply these settings to Speed Programs as well,
the next setting (Pressure Limit - Speed Programs) must be
enabled.
5− Pressure Limit (Speed Programs): Enable or disable maximum
system pressure limit for Speed Programs.