Summary of Contents for Nortek GXH09LSK4DL

  • Page 1 NORTEK GLOBAL HVAC, LLC Owner’s Manual Installation Instructions Split System Heat Pumps • Please read this owner’s manual carefully before operation and retain for future reference. •...
  • Page 3: Table Of Contents

    Contents Operation Notices Precautions............1 Parts Name.
  • Page 4 Explanation of Symbols DANGER WARNING CAUTION NOTICE...
  • Page 5: Precautions

    Precautions WARNING Operation and Maintenance • persons with reduced physical, sensory or mental • • by children. • • Otherwise, it may cause electric shock. • • shock. • shock or malfunction. • • • • you need to repair heat pump.
  • Page 6 Precautions WARNING • • malfunction. • • and disconnect power immediately, and then contact • • operation switch, please press this switch with an •...
  • Page 7 Precautions WARNING Attachment • • the unit. • • A circuit breaker must be used. • • note the capacity table. Air switch should include • • • listed on nameplate. Unstable power supply or incorrect • • any work related to electricity.
  • Page 8 Precautions WARNING • • • keep all cords and cables away from the copper tube. • • only. • cause electric shock. • • • accessible. • All wires of indoor unit and outdoor unit should be connected by a professional. •...
  • Page 9 Precautions WARNING • • Select a location which is out of reach for children and please put up a fence for safety purpose. • Working Temperature Range NOTICE: •...
  • Page 10: Parts Name

    Parts Name Indoor Unit Panel Air Outlet Remote Outdoor Unit Air Outlet NOTICE:...
  • Page 11 Parts Name Display Power Window ☼ ☼ Power Window Window ☼ ☼ Window ☼ ☼...
  • Page 12 Remote Control Buttons Display Screen Icons Operation Mode Temp. Display Type...
  • Page 13 Remote Control Button Description Note: • • remote controller. • • pump, operation indicator on indoor unit’s display is ON and indoor unit will Press this button to select your required operation mode. ☼ • • indicator • on indoor unit is ON. Under dry mode, fan speed can’t be •...
  • Page 14 Remote Control Button Description • Heat indicator Note: • minutes to blow air (actual delay time is depend on indoor ambient temperature). • ), medium ( Auto Note: • • at current position) • • , , , , • •...
  • Page 15 Remote Control Button Description mode. turbo function and icon will disappear. • • function and icon will disappear. temperature or outdoor ambient temperature on indoor unit’s display. As shown • or no display with remote controller, temperature indicator on indoor unit displays set temperature. •...
  • Page 16 Remote Control Button Description • after a set temperature is set up. • Until set temperature is set up, remote will display “88” • indicator displays current temperature and automatically returns to display set • will be displayed on the remote controller.
  • Page 17 Remote Control Button Description • reached desired time. icon resumes Note: • • • Combination Button Functions Energy-Saving Function Note: • • •...
  • Page 18: Operation Guide

    Combination Button Functions Child Lock Function When child lock function is on, press any button on the remote controller, the icon will blink three times without Temperature Scale Display Function Operation Guide on the heat pump.
  • Page 19 Replacing Batteries in Remote 1. Press the back side of remote controller Reinstall Notice • window on indoor unit. • more than 8m (25 ft), and there should be no obstacles in the path. • • • batteries. • replace batteries. Emergency Operation Panel Auxiliary...
  • Page 20 Cleaning and Maintenance WARNING • electric shock. • • Cleaning the Surface of Indoor Unit When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or damp cloth to wipe it. NOTICE: • Clean Filter 1.
  • Page 21 Cleaning and Maintenance WARNING • • • Notice: Preseason Checklist Notice: Post-Season Checklist Disposal and Recycling responsibly.
  • Page 22: Troubleshooting

    Troubleshooting General Analysis Malfunction Check Items Solutions • • from the wireless controller • • (25 ft). • Are there obstacles between • • Wireless controller • the remote controller at the won’t work unit. • • them if needed. •...
  • Page 23 Troubleshooting Malfunction Check Items Solutions • • • • • • Ask professional to replace circuit break or fuse. Heat pump won’t • • • Unit has restarted • Wait for 3 min, and then turn • • Reset the function. •...
  • Page 24 Troubleshooting Malfunction Check Items Solutions • • unit, which is normal. • • Cracking noise contraction of panel or other temperature. Error Codes • When heat pump malfunctions, the temperature indictor on indoor unit will required action to be taken. Error Code Troubleshooting Note:...
  • Page 25 Installation Clearances etc. allowed around indoor and outdoor units.
  • Page 26 Tools for Installation 8. Pipe cutter 9. Leak detector 5. Pipe expander 10. Vacuum pump Note: • • Proper power cord must be used. Installation Location Selection Basic requirement: in the air. Other places with special circumstances. Indoor Unit Outdoor Unit Select a location where the noise and and air outlet.
  • Page 27: Electrical Requirements

    Electrical Requirements Safety Precautions safety. Grounding Requirement shock.
  • Page 28 Indoor Unit Installation Step one: choosing installation location Step two: install wall-mounting frame screw locations on the wall. Step three: open piping hole shown as below.
  • Page 29 Indoor Unit Installation Note: • Outdoor much dust as possible. • Step four: outlet pipe 2. After selection position of outlet heat pump. case. Left the hole Left Left Rear unit Pipe Joint Union Nut Pipe nut with torque wrench.
  • Page 30 Indoor Unit Installation Wrench Union Nut Pipe Wrench tape. Step six: install drain hose pipe of indoor unit. Note: Outlet pipe Outlet • Hose Pipe indoor drain hose in order • Screw Panel Step seven: connect wire of indoor unit...
  • Page 31 Indoor Unit Installation indoor unit and then pull it out from the front side. Hole Power power cable with the wire clip. Note: • All wires of indoor unit and outdoor unit should be connected by a professional. • allowed. •...
  • Page 32 Indoor Unit Installation Step eight: bind up pipe cord and drain hose with tape. Gas Pipe Unit Liquid Pipe be bound separately at the end. Note: • hose and power cord for installation • at the bottom. indoor power and then separate the drain hose.
  • Page 33 Outdoor Unit Installation Step one: secure the support structure (select it based on installation needs) 2. Secure the support of outdoor unit on the selected location with expansion screws. Note: • • • order to install drain. • screws are needed. Step two: install drain joint Step three: secure outdoor (Only for cooling and heating...
  • Page 34 Outdoor Unit Installation Step four: connect indoor and outdoor pipes handle of outdoor unit and then Pipe Joint Screw Union Nut Handle below. of pipe. Liquid Pipe Liquid Gas Pipe them with screws. 09K, 12K Example 1 09K, 12K Example 2 Green White Green Green...
  • Page 35 Outdoor Unit Installation Note: • secure. • Step six: Arrange the pipes Wall inside. Note: • • the drain pipe connection on the indoor unit. hose must not rise. • hose must not slope up. hose must not slope up. outlet must not be placed in water.
  • Page 36 Vacuum Pumping Vent Nut Vacuum Pump Allen Wrench 15 min to check if the pressure Open min to check if the pressure Leak Detection detection. Apply soapy water at the suspected leak location and keep it there...
  • Page 37 After Installation Checklist • Items to check Possible result...
  • Page 38 Test Operation Explain operation and other important notes to client. operation. whether the operation is normal or not. connection connection pipe pipe (2051W) (3516W) (12306W)
  • Page 39 connection pipe additional 5m (16 ft) of connection pipe. table. Liquid Pipe Gas Pipe Ø 9.52 or 12 Ø 6 or 9.52 Ø 16 or 19 Ø 19 or 22.2...
  • Page 40 Pipe Expansion Method Note: E. Expand the port indoor and outdoor units. cutter. Pipe Hard Expander Pipe Note: diameter, please refer to the table A mm (in) Outer diameter mm (in) Pipe Hold indoor connection pipe and Smooth Surface nut on the pipe. Union Pipe Pipe...
  • Page 41 Optional Wired Controller 1.1.
  • Page 42 Optional Wired Controller 1.1. Number Symbol unit). Sleep function (Only sleep 1). Auto mode unit). Lock function. system.) SAVE unit).
  • Page 43 Optional Wired Controller 1.1. 1.2. Number Name 3 + 6 unit. 2 + 6 lock state. Repress them for 5s to exit this state.
  • Page 44 Optional Wired Controller 1.1. 1.2. Auto 1.3.
  • Page 45 Optional Wired Controller Auto 1.5. • • • display xx. Press Timer repeatedly the time Press Timer to cancel Press Enter/Cancel to...
  • Page 46 Optional Wired Controller Press Timer repeatedly the time Press Timer to cancel Press Enter/Cancel to...
  • Page 47 Optional Wired Controller 1.1. Press Function Press Enter/Cancel to repeatedly to enter Press Enter/Cancel to Press Function repeatedly to enter screen.
  • Page 48 Optional Wired Controller 1.1. Press Function Press Enter/Cancel to repeatedly to enter Press Enter/Cancel to Press Function repeatedly to enter...
  • Page 49 Optional Wired Controller 1.2. Press Function Press Enter/Cancel to repeatedly to enter Press Enter/Cancel to Press Function repeatedly to enter...
  • Page 50 Optional Wired Controller 1.1. function will be turned on automatically. Press Function Press Enter/Cancel repeatedly to enter Press Enter/Cancel to Press Function repeatedly to enter...
  • Page 51 Optional Wired Controller 1.2. Press Function Press Enter/Cancel to repeatedly to enter Press Enter/Cancel to Press Function repeatedly to enter screen.
  • Page 52 Optional Wired Controller 1.1. a. Lock Repress these two buttons at the same time for 5s to exit this function. Under the Lock state, no other buttons will operate. 1.1. meters (65 ft) (the standard distance is 8 meters (25 ft)). 1.2.
  • Page 53 Optional Wired Controller attention. until installation is complete. connection lines between the indoor and outdoor unit, a minimum of 20cm (8 in), otherwise the communication of the unit will probably work abnormally. controller communications lines must be shielded twisted pair wires.
  • Page 54 Optional Wired Controller 1.1. skilled personnel.
  • Page 55 Optional Wired Controller Error Error Jumper error protection Low pressure protection Outdoor fan 1 error protection Outdoor fan 2 error protection error protection current protection temperature protection circuited protection short circuited Sensor connection protection short circuited Outdoor ambient temperature sensor circuited short circuited circuit error"...
  • Page 56 66129920530...