NORTEK GLOBAL HVAC, LLC Flex Match Series Floor and Ceiling Type Indoor Unit (For North America) Owner's Manual Heat Pump Models: GFH09(2.6)FMK4DH GFH12(3.5)FMK4DH GFH18(5.3)FMK4DH GFH24(7.0)FMK4DH Please read this owner’s manual carefully before operation and retain for future reference.
Page 2
User Notice The total capacity of the indoor units connected can not exceed 150% of that of the outdoor units. The entire system (indoor and outdoor units) must have a dedicated power supply that can total power supply switch. Main power to compressor must be turned on 8 hours before air conditioner can be operated.
Flex Match 1 Safety Precautions Warning!: death. Caution! Warning! Air conditioner must use dedicated power supply circuit and switches for short circuit help. malfunction.
Flex Match 2 Installation 2.1 Installation Precautions The installation of the air conditioner must be conform to all national and local safety laws. Select a location where condensate water can be easily drained out. Select location where connections to outdoor unit and condensate drain are convenient. Unit should be installed more than 1m (3 ft) away from other electric appliances such as pool.
Page 9
Flex Match Model GFH09(2.6)FMK4DH GFH12(3.5)FMK4DH 1220mm 1158 GFH18(5.3)FMK4DH GFH24(7.0)FMK4DH Caution: The supply power for all indoor unit must be connected to outdoor unit. Open front panel. Remove the electrical box cover. and connect the power line and the communication line from the outdoor unit to the Replace the electrical box cover.
Flex Match 3.5 Drainpipe Installation (1). Use the included drain hose and clamp (2). (When drain hose is connected) Not to be lifted Drain hose Not to be (Accessory) (Accessory) Air outlet...
Page 12
Flex Match Pipe Flare Nut Pipe Spanner Pipe Diameter mm (in) (1). (2). (3). (4). with plastic tape. Notes:...
Page 13
Flex Match Air outlet Guide louver Front panel pipe Air inlet Suitable model GFH09(2.6)FMK4DH GFH12(3.5)FMK4DH GFH18(5.3)FMK4DH GFH24(7.0)FMK4DH Note: Illustation is for reference only. There may be a slight difference in appearance of different sizes. Indoor side state Outdoor side state Dry bulb Wet bulb Dry bulb...
Flex Match 6 Maintenance Warning! rinse air conditioner with water under any circumstances. conditioner.) Warning! Suggestion: will be overloaded and consume 6% Caution Do not wash with hot water (above the unit to be warped. compressor section for at least 8 hours before the air conditioner can be started up and run. Notice: All the operations above should be performed by professionals.
Page 15
Flex Match The desired temperature should be set at a moderate level to avoid of unnecessary condition the entire room.
Page 16
Flex Match on the nameplate of the unit. Only use fuses with specified capacity installed by professionals. Do not place any obstacles around the indoor and outdoor unit to avoid malfunction or poor performance. play with air conditioner. Do not install unit near a heat source. The heat may warp plastic parts.
Flex Match 8 Malfunction Analysis Warning! to be malfunctions, but actually are not. Check for the following conditions before calling for service. "Malfunction" Possible Analysis The unit will not restart after Unit emits and odor when first turned on. inside air conditioner. Is the unit turned off? The air conditioner will not run.
Page 18
Flex Match supply and contact service center for help.