Plumbing
1. Quick connect assembly with adapter (supplied).
2. These brewers must be connected to coffee stick
with operating pressure between 20 and 90 psi (0.138
and 0.620 MPa) from a 1⁄2" or larger supply line. A
shut-off valve should be installed in the line before the
brewer. Install a regulator in the line when pressure
is greater than 90 psi (0.620 MPa) to reduce it to 50
psi (0.345 MPa).
3. Vented drain available within 3.3 feet (1 meter) of
machine.
4. Flush the water line and securely attach it to the
inlet fitting at the rear of the brewer.
5. Turn on the water supply.
Water Treatment
1. No Chlorine.
2. Water Hardness 3 to 6 grains
3. Reverse osmosis System
NOTE: The water connections are at the lower rear of
the machine.
Location of the Serial Number
The serial number is located behind the puck bin on
the right wall across from the power switch.
The complete serial number will need to be docu-
mented on all work orders and warranty tags.
As directed in the International Plumbing Code
of the International Code Council and the Food
Code Manual of the Food and Drug Administra-
tion (FDA), this equipment must be installed with
adequate back flow prevention to comply with fed-
eral, state and local codes. For models installed
outside the U.S.A., you must comply with the ap-
plicable Plumbing /Sanitation Code for your area.