Bunn SURE TAMP AUTO Installation & Operating Manual page 7

Hide thumbs Also See for SURE TAMP AUTO:

Advertisement

Drain Install
1. Install drip tray bracket with 3 screws (included in bag).
2. Attach the short drain hose to the drip tray fitting.
3. Slide drip tray onto guide rails on front of machine.
4. Attach other end of drain hose to manifold as shown.
5. Attach long drain hose to back of manifold and route to
floor drain or sink, flowing downhill at all times.
6. Secure hose above the drain to maintain the air gap.
Water Supply Install
1. Ensure water is turned off.
2. Connect one end of the inlet hose assembly to the
adapter and the other end to the coffee stick.
3. DO NOT TURN ON THE MAIN WATER SUPPLY UNTIL
MILK PUMP BOX IS COMPLETELY CONNECTED. Check
for leaks; resolve any leak issues before proceeding.
Electrical Install
WARNING – Improper electrical installation will damage
electronic components.
1. Determine the available electrical service.
2. Ensure the proper voltage at the electrical source.
WARNING -
The brewer must be disconnected from the power source
until specified in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national elec-
trical codes to determine circuit requirements.
ELECTRICAL HOOK-UP (All Models)
CAUTION – Improper electrical installation will dam-
age electronic components.
1.
An electrician must provide electrical service.
2.
Determine the available on-site electrical service.
3.
Using a voltmeter, check the voltage and color
coding of each conductor at the electrical source.
4.
Uncoil the power cord completely and plug se-
curely into the outlet.
INSTALLATION-SURETAMP