Wiring Diagram - Rev C.2 - North Star M157115C.2 Owner's Manual

Hot water/steam pressure washer
Table of Contents

Advertisement

STANDARD CONTROL BOX DIAGRAM (115, 116)
CONTROL
BOX
2
BREAKER
ORANGE
RED
8
ALTERNATOR
RECTIFIER
GRAY
BLK
13
BRN= BROWN
BLK= BLACK
WHT= WHITE
BL= BLUE
Balloon #
1
Switch, Toggle
2
Breaker, Circuit, 5 AMP
3
LED, Red 12VDC-PW
4
Harness, Wire, Fuel Solenoid
5
Harness, Wire, Flame Sensor
6
Harness, Wire Flow Switch
7
Harness, Wire Thermistor /Hi-PSI
8
Harness, Wire Power W/Cap
9
Harness, Wire Flow Switch To Board
10
Harness, Wire Breaker To Switch
11
Controller, Temp. Assembly
12
Primary Control Board, 12VDC
13
Rectifier
Wiring Diagram – Rev C.2
11
3 POSITION
1
LEVER LOCK
SWITCH
8
8
RED
RED
RED
10
RED
LED
BURNER
3
BLK
5 POSITION
LEVER LOCK
Fig157115_15
Description
3
3 POSITION
TRIGGER
LEVER LOCK
BLK
RED
LED
BLK
THERMOSTAT BOARD
WHT
4
3
2
1
2 POSITION
LEVER LOCK
6
1 2 3 4 5 6 7
8
7
6
5
4
3
2
1
BLK
BLK
9
12
1 2 3
4
5
6
7 8
CONTROL
BOARD
8
4
5
PLUG
FLAME
SENSOR
BURNER FUEL
SOLENOID
67
TAPE RED WIRE
WHT
PLUG
7
PLUG
157115
157116
Part Number
Qty
777855
802307
777646
800649
800624
800594
799916
800708
800599
800458
802972
792287
799931
FLOW
SWITCH
HI PRESSURE
LIMIT
THERMISTOR
1
1
1
1
1
1
1
1
1
1
1
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

157115

Table of Contents