  • Page 1 Professional Audio Processor i4800/i3600 User Manual Page 1 / 34...
  • Page 2: Table Of Contents

    Index Chapter 1: Introduction ..............................3 Chapter 2: Technical Parameters ............................. 3 2.1 Features ................................... 3 Chapter 3 Functional Structure ............................5 3.1 LCD display function menu ............................6 3.2 Control buttons ................................ 6 3.3 Input section ................................6 3.4 Output section ................................. 7 Chapter 4: Introduction to PC Software ..........................
  • Page 3: Chapter 1: Introduction

    ▲Conference system Chapter 2: Technical Parameters 2.1 Features ▲ i3600 provides with 3 input channels and 6 output channels, i4800 provides with 4 input channels and 8 output channels ▲ Uncompromising top audio performance ▲ Unique and precise 96kHz/24bit digital signal processing ▲...
  • Page 4 Audio interface Cannon male and female Input resistance 11kΩ Maximum input level 16dBu/Line Output channel 8 balanced outputs, Line level Output impedance 100Ω AUDIO PERFORMANCE SPECIFICATIONS Frequency response curve 20Hz 40kHz(±0.5dB)/Line Noise floor 20Hz 20kHz, A- wt, - 93dBu THD+N - 90dB(@0dBu, 1kHz,A- wt)/Line 108dB(@16dBu, 1kHz,A- wt)/Line COMMUNITICATION PORTS AND INDICATORS...
  • Page 5: Chapter 3 Functional Structure

    Chapter 3 Functional Structure Front Panel OVERLOAD LIGHT LIMIT STATUS LIGHT 0dBu INPUT LEVEL LIGHT 0dBu INPUT LEVEL LIGHT - 24dBu INPUT LEVEL LIGHT BACK NEXT - 24dBu INPUT LEVEL LIGHT INPUT EDIT MUTE LIGHT MENU ENTER OUTPUT EDIT MUTE LIGHT BYPASS EXIT LCD DISPALY...
  • Page 6: Lcd Display Function Menu

    3.1 LCD display function menu LCD menu main interface 3.Current gear 4.Security lock 1.Device name 5.Device firmware version 2.Device IP 1. Device name: The user can customize and modify the name through the control software or the lower computer. 2. Device IP: When the device is connected to the software via TCP/IP, the device and the computer must be in the same IP domain, for example, the device IP is 169.254.xxx.xxx, and the computer IP should be 169.254.xxx.xxx.
  • Page 7: Output Section

    3.4 Output section EDIT/MUTE button (mute and edit button): Refer to the input section for function editing and operation mode. Chapter 4: Introduction to PC Software Software provides users quickly interact with all the parameters of one or more machines. It can store the configuration parameters of the machine in the machine and the computer, providing a very convenient way to preset scenes and parameters for different systems.
  • Page 8: Software Operating

    This software is a green version and does not require installation. The folder contains the following files or folders, all of which are indispensable. The green version of the software does not include the Microsoft .NET Framework 4.0 runtime. If necessary, please download and install it from the official Microsoft website. 5.3 Software operating Steps: Double- click the executable file in the folder , enter the main interface of the software, as shown in...
  • Page 9: Chapter 6 Software Interface Description

    Chapter 6 Software Interface Description Figure 6.1 main function interface 6.1 Introduction to Interface Module As shown in Figure 6.1, the module corresponding to the red word in the main interface of the function, each module is as follows: (1) Menu bar (2) Scan button (3) Setting button (4) Joint debugging button...
  • Page 10 6.1.1 Menu bar File Figure 6.1.1 "File" menu As shown in Figure 6.1.1 "File" menu: 1. New, new project, the project is restored to the initial open state. 2. Add new devices, add virtual devices, you can view all the functions of the device without affecting the specific device connected.
  • Page 11 The same type of equipment is required). Central control. Connection Figure 6.1.3 "Connection" menu As shown in Figure 6.1.3 "Connection" menu: Port: set the connection mode, port number and baud rate, confirm the connection mode and then select the corresponding port. Connect : connect and download the device parameters.
  • Page 12 automatic file to the boot file. Preset lock: lock the saved archive and set the password. Preset unlock: Enter the password to unlock the saved archive. Import preset: import a single preset file on the computer. Export the preset: export all the parameters of the current state to the computer, and generate a single preset file. Import preset package: import the preset package file containing multiple presets on the computer.
  • Page 13 Figure 6.1.7 Port connection interface 6.1.4 Link button To set the parameters of multiple devices at the same time, click the "Link" button, and the following figure 6.1.8 Device networking link interface will pop up. Select the device of the same model in the left frame, move to the group in the middle frame, and then select the synchronization settings required After pressing the "OK"...
  • Page 14 6.1.6 Computer IP address When the software is opened, it will automatically obtain the IP address of the computer system that the device is connected to. If there are 2 IP addresses, the first one is the IP address of the wireless network card by default, and the second is the IP address of the wired network card.
  • Page 15 It can display the level, gain, input mode, channel name and other information of each channel, control the corresponding channel gain, DSP function master switch, and turn on the input and output channel grouping joint adjustment function to achieve more flexible and practical operability. Page 15 / 34...
  • Page 16: Chapter 7 Function Interface Introduction

    Chapter 7 Function Interface Introduction 7.1 Main interface of input function Double- click in the function button , and the input function interface as shown in the Figure 7.1 below pops Figure 7.1 Channel input module As shown in the Figure 7.1, the phase polarity, mute, and input modes of the corresponding input channels can be operated;...
  • Page 17: Input Noise Gate

    Figure 7.2 Test signal setting interface As shown in the figure 7.2 above, it is divided into the upper half of the test signal switch setting options and the lower half of the channel selection test signal options. Configure the three commonly used test signals (sine wave, pink noise, white noise) to set the switch and gain value, green is open, red is closed.
  • Page 18: Input Parametric Equalizer (Peq)

    the value of the start control level. 7.4 Input Parametric Equalizer (PEQ) Double- click in the function button to pop up the parameter equalizer page as shown in the figure 7.4 below. The button in the upper right corner of the module can enlarge this interface for easier debugging. Figure 7.4 Input equalizer setting module 7.4.1 Function buttons As shown in Figure 7.4 above, the functions of the top buttons are.
  • Page 19 As shown in the figure above, the left side is the interface switching button for each channel. Click to switch the EQ channel, and the color is the currently selected channel. is the curve color of the EQ channel. For each channel's EQ curve display switch, check it to enable it to display the curves of other channels in the current channel interface.
  • Page 20: Dynamic Eq

    Select the preset item corresponding to the gear list on the left, and then click the function button on the right to realize the preset, recall, delete, and rename functions of the equalizer setting parameters. The preset parameters are saved to the computer in the designated folder in the software.
  • Page 21: Input Delay

    2. As shown in Figure, 4 kinds of DEQ modes: Boost Above, Boost Below, Cut Above, Cut Below, Max Gain. Figure. DEQ mode 3. Click to choose BYPASS type or PEQ type. 4. Threshold, Q value, Ratio, Max Gain, Attack, Frequency, and Release time for the DEQ corresponding parameters, which can be set by modifying the numeric box value.
  • Page 22: Input And Output With Fir

    7.7 Input and output with FIR Double- click in the function button , and the following figure 7.6 FIR function page will pop up. Upper right corner can zoom the interface. Figure 7.6 FIR setting module Setting area:  IMPORT: import FIR preset file to current channel. ...
  • Page 23: Matrix Mixing

     Num.Taps: taps, 8 steps in total. optional 256-2048.  ALT.(dB): depth, only available in Kaiser window.  Windows Type: window type selection.  STORE: click to save setting the parameters to the device channel. 7.8 Matrix mixing Double- click in the function button , and the following figure 7.8 matrix mixing function page will pop up.
  • Page 24: Output Delay

    Figure 7.9 Output equalizer function interface Double- click the function button , output equalizer function interface will pop- up shown in Figure 7.9, the parameter equalization function and operation mode are the same as input equalizer. But the output has increased the high and low pass filter function than the input, as described below.
  • Page 25: Output Compressor

    Figure 7.10 Output delay setting module Double- click in the function button , and the output delay function interface shown in Figure 7.10 will pop up. The function and operation method are the same as input delay. 7.11 Output compressor Double- click in the function button , the following Figure 7.11 output compressor function interface pops up.
  • Page 26: Output Module

    Double- click in the module button , and the following Figure 7.12 output limiter setting module will pop up. Figure 7.12 Output limiter setting module 7.13 Output module Double- click in the module button , and the output setting module shown in Figure 7.13 will pop up. Figure 7.13 Output setting module As shown in the figure above, you can control the polarity, mute, and gain settings of the corresponding output channel.
  • Page 27: Input And Output Channel Volume Monitoring

    7.14 Input and output channel volume monitoring 7.15 Channels link Click the channels link button between the input and output channels on the software homepage, channels link interface will pop up as following Figure 13.1. Figure 7.15 Channels link interface As shown in the figure above, the three lists from left to right are divided into channel list, group list, and parameter list: The channel list has listed all the channels that can be tuned together.
  • Page 28: Device List

    After grouping the list of default four groups, directly select the corresponding packet, if the channel list will be added directly to the channel assigned to the selected group, to remove the optional channel to be removed by clicking the Remove button below to add a button that is Can be removed to the channel list.
  • Page 29: Device Management

    Figure 7.17 Add Device Interface 7.18 Device Management Click "Device"- "Device " in the menu bar of the main software interface, and the device management interface shown in Figure 7.18 will pop up. Figure 7.18 Device management interface As shown in the figure above, the device information content displayed on the target device management interface can be selected in the device list at the top.
  • Page 30: Channels Copy

    Click "Device"- "Channels Names" in the menu bar of the main software interface, and the following Figure 7.19Channel Name interface will pop up. Figure 7.19 Channels name management As shown in the figure above, after entering the new name of the channel in the corresponding channel, click the OK button to save and update the name of the channel immediately.
  • Page 31: Device Preset

    7.21 Device Preset Click "Preset" in the menu bar of the main interface of the software, and the device preset interface in Figure 7.21 will pop up. Figure 7.21 Device Preset interface As shown in the above picture, the left side of the preset interface is the gear position, among which "0 automatic gear" is the system gear position, which automatically saves all parameters;...
  • Page 32 Click "System"- " Upgrade" in the menu bar of the main software interface, and the firmware upgrade interface shown in Figure 7.22 will pop up. Figure 7.22 Firmware Upgrade interface When the lower computer system of the device has been updated, after obtaining the upgrade file, you can open the firmware upgrade interface as shown in the figure above.
  • Page 33: Chapter 8 Introduction To Dante

    Chapter 8 Introduction to Dante The device can be equipped with a Dante module. Dante digital network audio technology is an uncompressed, professional- grade digital audio transmission technology (AoIP) based on Ethernet network transmission. Dante technology supports digital audio signal network transmission in audio systems even up to Dozens of units are set with hundreds of units to realize the interconnection and intercommunication of digital signals between devices, and have a stable and reliable signal synchronization function.
  • Page 34 After the routing configuration, Dante will memorize its own routing configuration. After turning off the power and restarting, Dante routing will restore itself. There is no need to configure the computer again. At this time, the Dante Controller control software can be closed. Page 34 / 34...