Part
Drain Pump
4 Check Points for Troubleshooting
1. S eparate the Drain Filter and check if any alien substances are inside the pump
(e.g. coins, buttons .., etc.) → Remove these if found.
2. C heck if the wire driving the pump has come loose → Take the relevant countermeasure
if necessary.
3. W hen water leaks, check the assembly status of the Clamp Hose, and Cap Drain →
Take the relevant countermeasure if necessary. Turn the filter counterclockwise to
remove the remaining water.
Figure
Description
5. Release the BAND RING (3EA) and
remove the HOSE (3EA).
6. Disconnect the wire.
7. Push the TUB inward slightly to remove the
PUMP.
Pump wire harness is connected to main
wire harness.