Siemens Portable Radio Installation Manual page 38

Table of Contents

Advertisement

IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
IEEE Test
C37.90.3
C37.90.2
C37.90.1
C37.90
Environmental Type Tests
IEC 60068-2-1
RUGGEDCOM RS8000
Installation Manual, 12/2021, C79000-G8976-1020-06
Test
HV Impulse
IEEE 1613
Clause
9
8
7
6
Test
Cold Temperature
6.2 EMC and Environmental Type Tests
Description
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Description
ESD
Enclosure Contact
Enclosure Air
Radiated RFI
Enclosure ports
Fast
Signal ports
Transient
DC Power ports
AC Power ports
Earth ground ports
Oscillatory
Signal ports
DC Power ports
AC Power ports
HV Impulse
Signal ports
DC Power ports
AC Power ports
Dielectric
Signal ports
Strength
DC Power ports
AC Power ports
Description
Test Ad
Certification
Test Levels
2 kVDC
5 kV  (Fail-Safe
Relay Output)
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV @ 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV common
mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC (Failsafe Relay)
1.5 kVDC
2 kVAC
Test Levels
Severity Levels
-40 °C (-40
°F), 16 Hours
Severity
Levels
 
 
 
 
 
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net ruggedcom rs8000

Table of Contents