1.2
TYPICAL CONFIGURATION
Figure 1 below indicates the typical set-up for an OSD2010 system.
1.3
ECHNICAL SPECIFICATIONS
SPECIFICATION
Optical Data Interface
Optical Data Rate
Optical Port Connectors
SFP Options
Alarms
Alarm Interface
Operating Temperature
Relative Humidity
Power Requirements
Power Connector
Alarm Connector
Indicators
Dimensions (mm)
Weight
PAGE 5
OPTICAL SYSTEMS DESIGN
FIGURE 1: OSD2010 TYPICAL CONFIGURATIONS
TABLE 1: TECHNICAL SPECIFICATIONS
Protocol transparent
10Mbps to 10Gbps
SFP
Short haul, Long haul, CWDM, single fiber operation, etc.
Please consult OSD SFP datasheets or contact OSD
SFP #1 Laser Fail
SFP #1 Loss of Received Optical Signal
SFP #2 Laser Fail
SFP #2 Loss of Received Optical Signal
4 Open drain outputs rated at 500mA @ 24V maximum;
Short to Ground when OK
Open Circuit when not OK or power off
-20°C to +75°C
0 to 95% non-condensing
+10V to +36V
4 way 5.08mm terminal block
6 way 3.5mm terminal block
2 x Laser OK/Not OK
2 x Received Optical Power OK/Not OK
60W x 94D x 26H (excluding flanges and connectors)
0.4kg
OSD2010 OPERATOR MANUAL
PERFORMANCE
or 22V to 28V
@ 4VA
DC
AC
102201001
DOC ID: 10117301