1.1.1 OVERVIEW The OSD2010 series is an industrially rated fiber mode converter. The unit can be used in a number of different applications such as a repeater, fiber mode converter or to add CWDM to existing fiber networks. The OSD2010 requires two SFP modules per unit to operate. It also has convenient LED status indicators and alarm outputs.
OPTICAL SYSTEMS DESIGN TYPICAL CONFIGURATION Figure 1 below indicates the typical set-up for an OSD2010 system. FIGURE 1: OSD2010 TYPICAL CONFIGURATIONS ECHNICAL SPECIFICATIONS TABLE 1: TECHNICAL SPECIFICATIONS SPECIFICATION PERFORMANCE Protocol transparent Optical Data Interface 10Mbps to 10Gbps Optical Data Rate Optical Port Connectors Short haul, Long haul, CWDM, single fiber operation, etc.
2 INSTALLATION AND OPERATION INTRODUCTION This section outlines the methods required to install and operate the OSD2010 successfully. It should be studied carefully if damage to the equipment or poor results are to be avoided. This equipment has been fully tested prior to dispatch and is ready for immediate operation. However it is advisable to check for external transportation damage before operation.
OPTICAL SYSTEMS DESIGN 2.2.2 OSD2010 DRAWINGS AND DIMENSIONS The OSD2010 is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws. 25.6 25.6 DETAIL A Ø8.5 R2.1 R2.1 DETAIL A 83.4...
Pin 4 FIGURE 3: OSD2010 POWER SUPPLY CONNECTIONS 2.3.2 ALARM CONNECTIONS The alarm contact closure output on the OSD2010 can be connected to the relay coil. Maximum ratings the OSD2010 can drive is 0.5A @ 24V (max) FIGURE 4: ALARM PINOUT...
Page 9
Ch B Open Circuit when not OK or Power off Ch B Short to GND (Pin 1) when OK Pin 5 Rx Ch B Fail Ch B Open Circuit when not OK or Power off Pin 6 Ground DOC ID: 10117301 PAGE 9 OSD2010 OPERATOR MANUAL...
Transmit Laser Fail Ch A Laser OK Green Transmit Laser OK No Received Signal Ch B Receive Signal OK Green Received Signal OK Transmit Laser Fail Ch B Laser OK Green Transmit Laser OK DOC ID: 10117301 PAGE 10 OSD2010 OPERATOR MANUAL...
OPTICAL SYSTEMS DESIGN 3 MAINTENANCE INTRODUCTION The following section outlines the fault-finding procedure for the OSD2010 modems. Please take note of the following: ▲ Personnel without appropriate training should not attempt any maintenance except that outlined below. If further maintenance is attempted you are warned that every care should be taken to ensure that ▲...
For warranty period, please call your local OSD distributor. REPAIRS Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a “Return Material Authorisation” (RMA) form and number before returning goods. Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its nominated authorised representative, for all repairs.
Page 16
OPTIC L Optical Systems Design Pty. Ltd. 7/1 Vuko Pl. Warriewood 2102 SYSTEMS P.O. Box 891 Mona Vale N.S.W. Australia 2103 Telephone: +61 2 9913 8540 DESIGN Facsimile: +61 2 9913 8735 Email: sales@osd.com.au Web Site: www.osd.com.au PTY LTD A.B.N. 83 003 020 504...