MAIN PARTS OF THE ELECTRICAL SYSTEM

>
CONTROL PANEL
"PC180-ST"
> 12V DISTRIBUTION BOX "DS3 0-ST"
relais, car battery recharging device, protection fuses.
> 4-RODS TANKPROBE - it measures the content of the
> TANK PROBE WITH SCREWS "SS/P" - signalization of full waste water tank.
> LEISURE BATTERY "B2" - it gives power to all the users.
> CAR BATTERY "B1".
ADVICE AND CHECKS
IMPORTANT Maintenance interventions on the electric implant must be carried out by
specialized personnel. Before carrying out maintenances disconnect the battery and the
230V alimentation line.
BATTERIES
Read with care the instructions of use and
maintenance of the batteries.
The acid kept in the batteries is poisoning and
corrosive. Avoid any contact with skin and eyes.
If the battery is completely discharged it needs
recharging for almost 10 hours. If discharged for
more than 8 weeks it may be damaged.
Check periodically the level of the liquid of the
battery (with acid); the GEL battery does not need
any maintenance but a countinuous recharging.
Check the correct tightening of the connection
binding screw and brush off the oxyde.
If the leisure battery is removed, isolate the positive
pole (in order to avoid short-circuits during an
accidental car engine starting).
In case of a longer stop, the services battery has to
be disconnected or recharged regularly.
BATTERY CHARGER
The battery charger must be installed in a dry and
ventilated place.
The installation of this device must be carried out by
specialized technicians.
In case of battery charger's misuse, the guarantee
falls off and the manufacturer declines all
responsibility for damages to people and things.
Do not carry out any maintenance when the battery
- mains' control, battery test, tank test.
0
- main relais, battery parallel relais (12V - 70A), fridge relais, pump
:
fresh
water tank, 4-levels visualization
charger is connected to the 230V power supply net.
Do not cover air intakes and assure an appropriate
ventilation.
Before disconnecting the battery charger from 230V
power supply, turn the security switch off.
TANK PROBES
Never let water in the tanks for long time, in order to
avoid foulings, especially in the waste water tank.
230V CUT-OUT BOX
Before taking away the cover, check that the 230V
socket is disconnected.
In order to avoid damages to the box, check the
correct tightening of the connections.
In order to cut power to the whole 230V system,
please take care that the 230V main switch must be
on the "0" (OFF) position.
Connect and disconnect the external 230V net only
when the main switch is off.
In case of automatic switch break, find the damage
before giving power again to the electrical system.
FUSES
Replace the fuses after finding out the real cause of
the damage only.
When the fuses are replaced respect the value of the
amperage established.